4. DIP SWITCH SETTING
(1) DIP SWITCH
Pin No. Function ON OFF Factory Setting
DS1-1 Auto Cutter Enable Disable OFF
2 CR Selection LF Enable LF Disable ON
3 Print Density Combination with (2)-J6 (See below) OFF
4 DTR/XON-XOFF XON-XOFF DTR/DSR OFF
5 Baud Rate OFF
6 " See below (3) OFF
7" OFF
8" OFF
(2) JUMPER
No. Function Short Open Factory Setting
J1 International Character set Open (Short circuit)
J2 " See below (4) Open (Short circuit)
J3 " Open (Short circuit)
J4 Paper Auto Loading Enable Disable Short circuit
J5 Print Drive System Variable division Fixed division Short circuit
J6 Print Density Combination with DS1-3 Short circuit
(Supplementary) See below(5)
J7 Not Used Short circuit
J8 Not Used Short circuit
(3) INTERFACE & BAUD RATE
DS1-8 7 6 5 Input Method Parity Baud Rate
OFF OFF OFF OFF Parallel Input -- --
OFF OFF OFF ON Serial Input None 1200 bps
OFF OFF ON OFF " " 2400 bps
OFF OFF ON ON " " 4800 bps
OFF ON OFF OFF " " 9600 bps
OFF ON OFF ON " " 19200 bps
OFF ON ON OFF " Odd 1200 bps
OFF ON ON ON " " 2400 bps
ON OFF OFF OFF " " 4800 bps
ON OFF OFF ON " " 9600 bps
ON OFF ON OFF " " 19200 bps
ON OFF ON ON " Even 1200 bps
ON ON OFF OFF " " 2400 bps
ON ON OFF ON " " 4800 bps
ON ON ON OFF " " 9600 bps
ON ON ON ON " " 19200 bps