Specifications

30
SELECT: Always non-active (“LOW”).
nFAULT: Signal to set “LOW” when the printer is in the error state (negative
logic).
PE: Signal to be output with No paper or near-end state (by command
setting) (positive logic)
Note: When using a command followed by FROM writing, printer may temporarily
become BUSY (DTR) at the time of write operation. In this case, as the
printer cannot make any processing, data transmitted may possibly be
discarded.
2) Electrical Characteristics
[1] Input signal level (nStrobe, Data0 ~ 7)
All input signals are C-MOS level.
”HIGH ” level: 2.0V min.
”LOW ” level: 0.8V max.
[2] Output signal level
All output signals are C-MOS level.
”HIGH ” level: 4.4V min.
”LOW ” level: 0.1V max.
[3] I/O conditions
All input/output signals are pulled up with 3.3 k.
[Printer side] [Host side]
Vcc
Twisted pair wire
[Printer side] [Host side]
Vcc
Twisted pair wire
3.3K
3.3K