Specifications
20
(3)
Cutter lock error
Explanation: Cutter operation is disabled. Abnormality occurred.
PE LED: OFF
ERROR LED: ERROR LED repeats blinking 2 times fast and blinking 1 time slow.
Restore Condition: Remove the fault and restore by pressing the FEED switch (with
MSW3-1 set to OFF) or by DLE EMQ 1 or 2 command (with MSW3-1
set to ON).
PE LED ERROR LED
OFF
Repeats blinking 2 times fast
and blinking 1 time slow.
3) Error impossible to restore
(1) Memory check error
Explanation: CPU self-diagnoses the circuit. When it detects abnormality in external RAM
memory, ERROR LED blinks quickly.
PE LED: OFF
ERROR LED: Blinking quickly
Restore Condition: Irreparable
However, it can be restored by turning power OFF, replacing external
RAM, and removing the cause of the abnormality.
PE LED ERROR LED
OFF
ERROR LED blinks
quickly.