Specifications
71
●
Features:
UL 1449 & UL1414 Recognized
(File E96234 & E165829)
100% Lead-Free (RoHS Compliant)
IEC60950 Line Isolation
3.1 mm Internal Electrode Gap
(Meets VDE Gap Requirement)
ISO 9001 Certified
●
Applications:
Transient Voltage Surge Suppression (TVSS)
AC Line Input Protection
Power Supplies
CATV Systems
Antennas
Test Equipment
Set-top Boxes
Two Electrode Gas Tube Surge Arrester
Y08SV-272B
Electrical Characteristics
1. DC Breakdown Voltage 5KV/sec 2430 - 300V
2. Impulse Breakdown Voltage 1KV/
μ
sec
<3900 V
3. Insulation Resistance DC 1000 V >10,000 M-ohm
4. Capacitance 1 MHz <1.0pF
5. Impulse Discharge Current 8/20
μ
sec 10kA 1 Time
8/20
μ
sec 3kA Each Polarity 10 Times 3 Min. Intervals
6. Impulse Life 8/20
μ
sec 100A
> 300 times
1-2 Minute lntervals
After Life Tests
7. DC Breakdown Voltage 5KV/sec 2230-3170V
8. Impulse Breakdown Voltage 1KV/
μ
sec
<4200 V
9. Insulation Resistance DC 1000 V >1 M-ohm