SUPER FOAM DOMETM Operating Instructions P/N 100211 (110 VAC)
Thank you for purchasing this SUPER FOAM DOMETM ! ! ! As you will notice from the table of contents, the manual for your new product is quite extensive. To guarantee perfect and successful work with this machine, please take some time to read the manual carefully. And finally, we believe you will enjoy years of great foam effects if you care for and maintain your SUPER FOAM DOMETM. CITC 2100 196th St. S.W., Ste. 138 Lynnwood, WA 98036 (888) 786-CITC www.citcfx.
Contents 1. Set of Equipment Supplied 3 2. Accessories 3 3. Description 4 4. Safety Instructions 4 5. Operating the Super Foam DomeTM 5 5.1 5.2 5.3 5.4 5.5 5.6 Selecting the location Electrical Power Requirements Hooking things up Operating the machine Cleanup Troubleshooting 6. Service and Maintenance 10 6.1 Super Foam DomeTM Pump Information 6.2 Getting the most from your Super Foam DomeTM Pump 7. Technical Data 11 8.
1. Set of Equipment Supplied " 1 Super Foam DomeTM Unit " 1 Super Foam DomeTM pump with fittings " 4’ garden hose with male end for pump intake " GFI Box Assembly " 25’ plastic tubing w/2ea push-con fittings " Kit: Gloves, safety goggles and bolts " “Keep Foam Fun” Safety Banner " Instruction booklet, catalog, warranty card " Shield set " Note: you will need to provide a 55 gal. plastic barrel with at least a 2” opening 2.
3. Description of the Super Foam DomeTM The Super Foam DomeTM makes massive amounts of foam (500 cubic feet per minute (14m3/min)) quickly and harmlessly with its high-powered quiet fan. It will actually fill a 20’ x 20’ x 6’ pit in less than 5 minutes. The improved white modulator has a thicker, higher output of foam. You can dance in it, ride through it and make clouds and snow effects with it.
o WARNING: NEVER plug pump in without Super Foam DomeTM unit (fan) being on. Electrical damage to your motor will occur and as this would immediately void the oneyear warranty. o GLASS: No glassware or breakables allowed in foam area. If glass breaks in foam area, evacuate all persons immediately until cleaned up. o SUPERVISION: No pushing, shoving or horseplay allowed. No diving, running or body bowling. Intoxicated individuals should leave foam area. o EXPOSURE TO FOAM: Avoid prolonged eye contact.
2. You must have both units connected through the Ground Fault Interrupter (GFI) in order to use this device. 1. Plug GFI into a well-grounded 110VAC/20A circuit. If you have any doubt about the circuit’s safety ground, plug-in testers are available to test the outlet. If in doubt, discontinue trying to power this unit until the outlet can be checked by an electrician. 2. With the power switch in the OFF position, verify that the red LED in the plug turns on. 3.
If contact with skin, wash with water. Prolonged contact with skin may cause irritation. Wash with water. If clothing is wet with material, change to clean clothes and wash affected skin. Not food quality. Do not digest. If digested, treat as dish soap. Odor from this product may be irritating to some individuals. Discontinue use and remove to fresh air. As with all surfactants, care must be used at all times. Rinse with plenty of water if contact occurs.
o Never turn on the pump without the Super Foam DomeTM fan. This will cause fluid to pour from fan area to floor. Unplug the pump if needing to test only the fan. When done, switch GFI off and plug pump in to GFI to operate the system by switching on the pump and Super Foam DomeTM fan at the same time. Never operate without all lines and hoses attached. 2. Unit will turn on when you switch on the red power switch on the GFI.
o If the fan rotates, but is not very fast: Power loss will cause this unit to not function properly. Try plugging the fan into another outlet that is closer. Change the power switch on the unit to the faster speed. Does it rotate faster? You need to change to a heavier (minimum 12 awg) extension cord. Is the power supply dedicated solely to this unit? Are you sharing power with other equipment? Try disconnecting any other loads on the same circuit.
6. Service and Maintenance 6.1 Super Foam DomeTM Pump Information The Super Foam DomeTM pump has built-in thermal overload protection, which means the unit will automatically shut-off when it senses it could reach an overheat level. Once cooled down, it will reset and is ready to pump again. Once the area to be drained reaches a maximum of 1/8", unplug the pump or add more foam. Power cord must always be plugged into the GFI.
7. Technical Data Super Foam DomeTM 110V Technical Data P/N 100216 Super Foam DomeTM Dimensions 19” x 19” x 19” (48cm x 48cm x 48cm) Super Foam DomeTM Weight 28 lbs (12 kg) (plus pump: see below) TM Super Foam Dome Power 1 hp: 110 VAC, 60 Hz, 20 A Super Foam DomeTM Power Cord 25’ (7.6 m) GFI switch box Two outlets with lighted power switch GFI Power Cord 8’ (2.5m) Fluid pump High-pressure diaphragm pump 45 psi (3.1 bar) / 1.4gpm (5.3 lpm) Wt/Dims fluid pump 5lbs (2.
8. Limited Warranty Conditions for the Super Foam DomeTM 1. Subject to the following conditions we will repair any defect or fault in the unit if it is caused by a proven factory fault and has been advised immediately after appearance and within 30 days of delivery to the end user. Insignificant deviations of the regular product quality does not guarantee replacement rights, nor do faults or defects caused by water, by generally abnormal environment conditions or Force Majeure. 2.
If you should send the unit for service, obtain your RMA # by calling CITC. Payment arrangements for repair must be made before receiving RMA # in case unit is not covered under Limited Warranty. Send unit to: CITC RMA # XXXXXXX 2100 196th Street SW Suite #138 Lynnwood, WA 98036 Tel: (888) 786-CITC or (425) 776-4950 Fax: (425) 776-5129 Website: www.citcfx.com E-mail: info@citcfx.com 2100 196th St. SW, #138, Lynnwood, WA 98036-7083 425-776-4950 # FAX: 425-776-5129 www.citcfx.com # info@citcfx.