Specifications
Table Of Contents
- 560 ENCORE OPERATING MANUAL

SECTION I
MODEL 560 DESCRIPTION AND SPECIFICATIONS
STANDBY FLIGHT INSTRUMENTS
1. A satisfactory preflight test must be accomplished on the standby gyro system.
2. The standby flight display and standby HSI must be functioning prior to takeoff.
HIGH FREQUENCY (HF) / AUTOMATIC DIRECTION FINDER (ADF) SYSTEMS
The ADF bearing information may be erratic when keying the HF transmitter. Should this occur,
disregard the ADF bearing during periods of transmission.
TRIM
Prior to the first flight of each day, the elevator trim check in Section IV, Operating Information, must
be satisfactorily completed.
OXYGEN MASK
The pressure demand oxygen masks must be properly stowed in their containers to qualify as a
quick-donning oxygen mask.
NOTE
Headsets, eyeglasses or hats worn by the crew should be removed prior to donning
the oxygen masks.
SUPPLEMENTAL OXYGEN SYSTEM
Crew and passenger oxygen masks are not approved for use above 40,000 feet cabin altitude.
Prolonged operation of passenger masks above 25,000 feet cabin altitudes is not recommended.
NOTE
Passenger masks are intended for use during an emergency descent to an altitude not
requiring supplemental oxygen.
AIRPLANE BATTERY
If the BATT O'TEMP light illuminates during ground operation, do not take off until after the proper
maintenance procedures have been accomplished.
I
56OMB-01 Configuration AA 1-21