Specifications

SECTION VI
MODEL 560 EMERGENCY PROCEDURES
BATTERY OVERTEMPERATURE (BATT O’TEMP WARNING LIGHT ON)
NOTE
If current decreases and battery voltage is 1 volt less than generator voltage in 30
seconds to 2 minutes, monitor battery overheat annunciator for possible change.
IF NO VOLT/AMP DECREASE (Battery Relay Stuck)
4. BATT Switch - BATT.
5. BATTERY DISCONNECT Switch (LH panel) - LIFT GUARD AND DISC.
6. Amperage - NOTE DECREASE.
IF BATT O’TEMP WARNING LIGHT DOES NOT GO OUT OR >160° WARNING LIGHT
ILLUMINATES
7. Land as soon as possible.
IF BATT O’TEMP WARNING LIGHT GOES OUT
7. BATTERY DISCONNECT Switch (LH panel) - NORM AND CLOSE GUARD.
8. Land as soon as practical.
IF VOLT/AMP DECREASE
4. BATT Switch - OFF (voltmeter will be inoperative).
IF BATT O’TEMP WARNING LIGHT GOES OUT
5. BATT Switch - BATT.
6. Continue flight (as desired).
CAUTION
f
PROLONGED OPERATION WITH THE BATTERY DISCONNECT SWITCH
DISCONNECTED AND THE BATT SWITCH ON WILL GRADUALLY DEPLETE THE
BATTERY THROUGH THE BATTERY DISCONNECT RELAY. STARTER
ASSISTED AIRSTARTS WILL NOT BE AVAILABLE.
f
AFTER LANDING, REFER TO AIRPLANE MAINTENANCE MANUAL FOR PROPER
MAINTENANCE PROCEDURES, AS DAMAGE TO THE BATTERY MAY HAVE
OCCURRED.
1. Amperage - NOTE.
2. BATT Switch - EMER.
3. Amperage - NOTE DECREASE.
I
56OMB-01 Configuration AA 6-17