Specifications
Table Of Contents
- 560 ENCORE OPERATING MANUAL

SECTION II
AIRPLANE AND SYSTEMS
MODEL 560
7. F/W
SHUTOFF
L R
The amber firewall shutoff light advises that the left and/or right fuel and hydraulic
shutoff valves are closed
8. FUEL
GAUGE
L R
The amber fuel gauge light advises that the fuel gauging system has detected an
error.
9. FUEL
BOOST
L R
The amber fuel boost ON light advises that electrical power has been applied to the
left and/or right boost pump.
10. LO FUEL
LEVEL
L R
The amber fuel low light advises that the fuel quantity in the left and/or right tank is
below approximately 185 pounds or less.
11. LO FUEL
PRESS
L R
The amber fuel low pressure light advises that the fuel pressure is low in left and/or
right systems.
12. FUEL
FLTR BP
L R
The amber fuel filter bypass light advises that bypass of the left and/or right fuel
filter is impending.
13. LO HYD
FLOW
The amber hydraulic flow low light advises that left and/or right hydraulic system
flow is below approximately 0.35 to 0.55 gallons per minute.
14. LO HYD
LEVEL
The amber hydraulic low level light advises that the fluid in the hydraulic reservoir
is low.
15. HYD
PRESS
The amber hydraulic pressure ON light advises that the hydraulic system is
pressurized.
16. LO BRK
PRESS
The amber power brake low pressure light advises that the power brake hydraulic
pressure is low.
17. ANTISKID
INOP
The amber antiskid inoperative light advises that the antiskid system is inoperative.
18. GEN
OFF
L R
The amber generator OFF light advises that left and/or right generator is not
connected to the airplane bus. Illumination of both left and right lights will trigger the
master warning system which will illuminate the master warning light.
19. INVTR
FAIL
1 2
The amber inverter fail light advises that the number 1 or number 2 inverter output
voltage is above 130 VAC or below 90 VAC. The failure of either inverter also
triggers (AC FAIL). Resetting the master warning reset switch will extinguish the AC
FAIL annunciation unless both inverter lights are illuminated.
20. AFT
J BOX
LMT CB
The amber aft j-box LMT light flashes and the master caution illuminates to advise
that the left and/or right crossfeed limiters have blown, disabling crossfeed of
electrical power from left bus to right bus or visa versa. Pressing the master caution
will cause the flashing annunciator to change to steady on and the master caution to
extinguish.
The amber aft j-box CB light flashes and the master caution illuminates to advise
that the left and/or right start control PCB circuit breaker has opened, disabling the
electrical start system. Pressing the master caution will cause the flashing
annunciator to change to steady on and the master caution to extinguish.
I
2-64 Configuration AA 56OMB-01