ELECTRICAL CONNECTIONS (WITH GROUNDING INSTRUCTIONS
ELECTRICAL
CONNECTIONS
FOR ALL DRYERS
Dryers must be electrically grounded by a separate #14 or larger
green wire from the grounding terminal within the service connection
box, to a cold water pipe. In all cases, the grounding method must comply
with local electrical code requirements; or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 or the
Canadian Electrical Code, CA C22.1—Latest Edition.
See wiring diagram furnished with dryer. Your dryer is completely
wired at the factory and it is only necessary for the electrician to connect
the power leads to the wire connectors within the service connection box
on the rear of the dryer. Do not change wiring without consulting the
factory, as you may void the factory warranty. DO NOT
CONNECT THE DRYER TO ANY VOLTAGE OR CURRENT
OTHER THAN THAT SPECIFIED ON THE DRYER RATING
PLATE. (Wiring diagram is located on rear wall of dryer.)
All panels must be in position before operation of dryer.
«Attention. Lors des opérations d’entretien
des commandes, ètiqueter tous les fils avant
de les dèconnecter. Toute erreur de câblage
peut être une source de danger et de panne»