Section 6
NetMaster Troubleshooting
Models with NC, NR, NX, NY, ZC, ZR, ZX and ZY
Control Suffixes
25.No Infra-red (IR) Communication
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Check the following:
- IR communication disabled by
manual programming.
- Is the IR window on the control
covered or blocked.
- if needed, change control
board.
Check the following:
- low battery in handheld
communication device.
- low battery in the Symbol SP
T 1800
infra-red box.
- poor connection between IR cup and
Micro-Wand.
- poor connection between IR box and
Symbol SPT 1800.
- is the IR window covered or blurred
on the control.
Communication
sequence checks
out.
Aim handheld
communication
device closer and
try again.
Is there a response of
any kind from the
electronic control?
Does the control
respond?
Does the electronic
control display E:OF
or -C-?
NO
YES
-C-
"E:OF"
NO
NO
YES
Gas and electric heat.
Single and three phase
power supply.
TMB1991S
Attempt to
communicate with
the electronic
control from
the handheld
communication
device
Replace the
electronic control.