Micro Display Control (MDC) Troubleshooting
20.Motor Will Not Start/Run (continued)
Please see following 2 pages for wiring diagram information.
Is there voltage across
terminals 1 & 4 of
cylinder motor?
Does the cylinder
motor run?
Correct wiring
between cylinder
motor and motor
control relay.
Replace cylinder
motor.
NO
NO
YES
YES
Motors are
operational.
Note: For high voltage three phase supply (380 volts
or higher), the cylinder and fan motors are supplied
by L1, L2, L3 through the motor relay te
rminals T1,
T2,
T3. Make the appropriate adjustments when
doing voltage checks.
(9)