Owner`s manual
Page 41
Troubleshooting Chart
Replace timer.
Check all valves in steam supply and return. Make
sure they are open.
Remove and clean. Replace if defective.
On dryers using solenoid temperature control, thermo-
stat controls operation of solenoid valve by advancing
thermostat.
On dryers using solenoid temperature control, thermo-
stat controls operation of solenoid valve. If defective,
replace thermostat.
Check for inlet and outlet marking on check valve and
invert if necessary.
Remove plug and blow down strainer or remove and
clean thoroughly if heavily clogged.
Check piping per steam installation instructions.
Check trap for size and capacity. If dirty and slug-
gish, clean thoroughly or replace. Check return line
for high back pressure, or another trap charging
against the trap functioning improperly.
Check timer to see if operating.
Dryer does not stop at end
of time period (6).
Dryer runs no steam to
coils.
Water in steam line.
Basket does not reverse.
Defective timer.
Valve closed.
Steam trap blocked.
Solenoid valve.
Thermostat.
Check valve in-
stalled incorrectly.
Strainer clogged.
Steam piping
installed incorrectly.
Trap not functioning.
Reversing timer.
TROUBLE CAUSE REMEDY