Owner`s manual

Page 38
Troubleshooting Chart
TROUBLE CAUSE REMEDY
Check fuses on circuit breakers. Make sure main
control switch is on.
Check power source; voltage, phase and frequency
must be the same as specified on electrical rating plate.
Turn timer clockwise to desired time setting.
Check wire connections in electrical box on rear of
dryer.
Check coils and contacts.
Check voltage at motor terminals. Voltage must be
within + 10% of voltage shown on motor rating plate. If
not, check with local power company for recommended
corrective measures.
Check with local power company to insure that wiring
is adequately sized for load.
Check all electrical connections and tighten any loose
connections.
Check installation sheet in service manual for recom-
mended make-up air openings.
Clean lint accumulation on and around motors.
Close door.
Adjust switch by removing cover and bend actuator
lever to clear switch button 3/8" (10 mm) with cover in
place.
Replace switch.
Replace contactor.
Replace timer.
Replace V-belt.
Adjust belt tension.
Tighten set screw.
Remove load.
No power.
Incorrect power.
Time off.
Loose wiring
connections.
Defective starting
relay.
Low voltage.
Inadequate wiring.
Loose connections.
Inadequate air.
Poor housekeeping.
Loading door open.
Door switch out of
adjustment.
Defective door
switch.
Defective basket
motor contractor.
Defective timer.
V-belt broken.
V-belt loose.
Motor pulley loose.
Basket overloaded.
Motor will not start.
Motor tripping on thermal
overload.
Basket motor will not run.
Dryer does not stop at end
of time period.
Motor runs, but basket will
not revolve.