Electrical Connections - All Dryers
ELECTRICAL
CONNECTIONS
Dryers must be electrically grounded by a separate #14 or larger green
wire from the grounding terminal within the service connection box, to
a cold water pipe. In all cases, the grounding method must comply
with local electrical code requirements; or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 or the
Canadian Electrical Code, CA C22.1.
See wiring diagram furnished with dryer. Your dryer is completely
wired at the factory and it is only necessary for the electrician to
connect the power leads to the wire connectors within the service
connection box on the rear of the dryer. Do not change wiring without
consulting the factory, as you may void the factory warranty. DO NOT
CONNECT THE DRYER TO ANY VOLTAGE OR CURRENT
OTHER THAN THAT SPECIFIED ON THE DRYER RATING
PLATE. (Wiring diagram is located on rear wall of dryer.)
All panels must be in position before operation of dryer.
ELECTRICAL
CONTROLS SERVICE
Caution: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
«Attention. Lors des opérations d’entretien
des commandes, ètiqueter tous les fils avant
de les dèconnecter. Toute erreur de câblage
peut être une source de danger et de panne»