Specifications

7-7
Cisco XR 12000 Series Router SIP and SPA Software Configuration Guide, Release 3.2
Release 3.2, OL-6396-01, Rev.A1 January 9, 2006
Chapter 7 Upgrading Field-Programmable Devices
Troubleshooting Problems with SPA FPD Image Upgrades
When a SPA is in the FAILED state, it may not register itself with the FPD upgrade mechanism. In this
case, you will not see the SPA listed when you use the show hw-module fpd command. In order to verify
the state of a SPA, use the show hw-module subslot error command and the show hw-module subslot
status command.
Performing a SPA FPD Recovery Upgrade
To recover a SPA from the FAILED state due to a corrupted FPD image, you must manually shutdown
the SPA. Use the hw-module subslot subslot-id shutdown powered command in global configuration
mode to administratively shutdown the SPA. Once the SPA is shutdown, then you can use the upgrade
hw-module fpd command in admin EXEC mode, with the force option in order to restart the FPD
upgrade process.
Verifying a Successful Upgrade
After the upgrade process is complete, you can use the show hw-module fpd command to verify that
the FPD image on the SPA has been successfully upgraded.
Use the show hw-module subslot status command to verify that the SPA is up and running:
RP/0/0/CPU0:Router# show hw-module subslot status
BAY 0/3/0 status info:
------------------------
SPA inserted: YES
SPA type: 5xGE SPA
SPA operational state: READY
SPA powered: YES
SPA in reset: NO
SPA insertion time: Mon Feb 28 13:44:23 2005
SPA last time ready: Mon Feb 28 13:45:10 2005
SPA uptime [HH:MM:SS]: 19:04:47
BAY 0/3/1 status info:
------------------------
SPA inserted: YES
SPA type: 1xOC192 POS/RPR HHSPA with XFP
SPA operational state: READY
SPA powered: YES
SPA in reset: NO
SPA insertion time: Mon Feb 28 13:44:25 2005
SPA last time ready: Mon Feb 28 13:45:05 2005
SPA uptime [HH:MM:SS]: 19:04:52