Installation guide

8 Release Notes for Catalyst 6000 Family Software Release 5.x
Open and Resolved Caveats in Software Release 5.3(4)CSX
The set port qos trust command and the trust-ipprec and trust-dscp port keywords are not
allowed on 10-, 10/100-, and 100 Mbps ports. Instead, configure ACLs with the trust-cos,
trust-dscp, and trust-ipprec ACE keywords. Note that the trust-cos port keyword can be used
on 10-, 10/100-, and 100 Mbps ports to enable receive queue drop thresholds.
24-port 100FX Switching Modules (WS-X6224-100FX-MT) with a hardware version of 1.1 or
lower only support IEEE 802.1Q VLAN trunking; they do not support ISL trunking. Do not
configure ISL trunks on 24-port 100FX Switching Modules (WS-X6224-100FX-MT) with a
hardware version of 1.1 or lower. The restriction against ISL VLAN trunking is the only known
problem with hardware version 1.1 or lower of these modules. If you do not require ISL VLAN
trunking, these modules are fully functional. The ISL VLAN trunking problem has been
corrected in hardware version 1.2 or later of these modules. If you wish to return a
WS-X6224-100FX-MT module with a hardware version of 1.1 or lower, contact Cisco Systems.
You can identify WS-X6224-100FX-MT hardware versions using one of the following two
methods:
Command-line interface (CLI) method—Use the show version command to identify the
hardware version of the WS-X6224-100FX-MT module as follows:
console> show version
< ... output truncated ... >
Mod Port Model Serial # Versions
--- ---- ------------------- ----------- --------------------------------------
< ... output truncated ... >
5 24 WS-X6224-100FX-MT SAD02470006 Hw : 1.1
< ... output truncated ... >
console>
The example shows a WS-X6224-100FX-MT module with a hardware version of 1.1; this
version does not support ISL VLAN trunking.
Physical inspection method—Look for the part number is printed on a label on the outer edge
of the component side of the module. Versions 73-3245-04 or lower do not support ISL
trunking.
There is a cabling issue with the 48-Port 10/100TX Switching Module (WS-X6248-TEL). The
WS-X6248-TEL module RJ-21 connectors do not support Category 3 RJ-21 telco connectors
and cabling. Using Category 3 connectors and cabling causes carrier sense errors. The module's
connectors are keyed for Category 5 telco connectors and cables. You must use Category 5 RJ-21
telco connectors and cables.
We recommend that you do not use more than 1500 multicast groups with GMRP. This restriction
does not apply to IGMP.
Open and Resolved Caveats in Software Release 5.3(4)CSX
This section describes open and resolved caveats in supervisor engine software release 5.3(4)CSX.
Open Caveats in Software Release 5.3(4)CSX
This section describes open caveats in supervisor engine software release 5.3(4)CSX.
If you remove a line module at the same time as you remove an active supervisor from a Catalyst
6000 family switch that is in a redundant supervisor configuration, the switch may become
unreachable. To prevent this, wait at least 5 seconds after removing an active supervisor to allow
the switchover to occur before you remove a line card (CSCdp59829)