Installation guide

Release Notes for Catalyst 6000 Family Software Release 5.x 25
Resolved Caveats in Software Release 5.2(3)CSX
If the switch is in VTP client mode, entry of a copy device:filename config command may
generate messages about nonexistent VLANs. Wait until the show vlan command displays the
VLANs and then enter the copy command again. This problem is fixed in software release
5.3(1)CSX. (CSCdm07337)
Do not configure anymodule so that the number of GVRP-enabled ports, including the individual
physical ports in GVRP-enabled EtherChannels, times the number of VLANs on the module,
exceeds 720. This problem is fixed in software release 5.3(1)CSX. (CSCdm18614)
The MSM is not supported as a SPAN source port. Configuring the MSM as a SPAN source port
generates a “Failed to configure source port” message. If you configure the MSM as a SPAN
source port, all subsequent SPAN source port configuration commands for that SPAN session
generate the same message until you remove the MSM from the source port list with a set span
disable mod_num/port_num command. This problem is fixed in software release 5.3(1)CSX.
(CSCdm20365)
When you turn off the power on any module, you cannot turn the power back on through SNMP.
The workaround is to use the CLI command set module power up mod_num. This problem is
fixed in software release 5.3(1)CSX. (CSCdm23288)
Occasionally during bootup, a bus ASIC sequence error syslog message is reported to the console
as follows:
%SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occurred on module 3 (asic=1,
srcidx=0x0, seq=28)
This message might be generated for any module. Ignore this message. This problem is fixed in
software release 5.3(1)CSX. (CSCdm32301)
This bug does not effect system operation. The 48-Port 10/100TX Switching Modules
(WS-X6248-TEL and WS-X6248-RJ-45) “Send admin” flow control field (show port
flowcontrol mod_num/port_num) might show “desired” when the port is connected as well as
when it is not connected or disabled. This problem is fixed in software release 5.3(1)CSX.
(CSCdm37747)
If Gigabit channel ports and 10/100BaseTX channel ports are used as SPAN source ports, the
Gigabit channel ports might not show up in the Oper Source ports field. This problem is fixed
in software release 5.3(1)CSX. (CSCdm39024)
This bug does not effect system operation. On disabling the Multilayer Switch Module (MSM),
the show module command shows “faulty” instead of “disabled”. This problem is fixed in
software release 5.3(1)CSX. (CSCdm42419)
If all ports of a channel are disturbed by either resetting the module(s) on the remote end, or due
to a broadcast storm, the switch might not transmit or receive any GMRP control packets. The
workaround is to disable and then enable the GMRP feature on the switch which experiences this
problem. This problem is fixed in software release 5.3(1)CSX. (CSCdm45744)
Resolved Caveats in Software Release 5.2(3)CSX
This section describes resolved caveats in supervisor engine software release 5.2(3)CSX.
Occasionally during bootup, a bus ASIC sequence error syslog message is reported to the console
as follows:
%SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occurred on module 3 (asic=1,
srcidx=0x0, seq=28)
This message might be generated for any module. Ignore this message. This problem is fixed in
software release 5.3(1)CSX. (CSCdm32301)