24 Release Notes for Catalyst 6000 Family Software Release 5.x
Open and Resolved Caveats in Software Release 5.2(3)CSX
This bug does not effect system operation. The 48-Port 10/100TX Switching Modules
(WS-X6248-TEL and WS-X6248-RJ-45) “Send admin” flow control field (show port
flowcontrol mod_num/port_num) might show “desired” when the port is connected as well as
when it is not connected or disabled. This problem is fixed in software release 5.3(1a)CSX.
(CSCdm37747)
If Gigabit channel ports and 10/100BaseTX channel ports are used as SPAN source ports, the
Gigabit channel ports might not show up in the Oper Source ports field. This problem is fixed
in software release 5.3(1a)CSX. (CSCdm39024)
This bug does not effect system operation. On disabling the Multilayer Switch Module (MSM),
the show module command shows “faulty” instead of “disabled”. This problem is fixed in
software release 5.3(1a)CSX. (CSCdm42419)
Occasionally, disabling GVRP caused an exception. This problem is fixed in software release
5.3(1a)CSX. (CSCdm44130)
If all ports of a channel are disturbed by either resetting the module(s) on the remote end, or due
to a broadcast storm, the switch might not transmit or receive any GMRP control packets. The
workaround is to disable and then enable the GMRP feature on the switch which experiences this
problem. This problem is fixed in software release 5.3(1a)CSX. (CSCdm45744)
If you delete the RMON alarmEntry or if you modify the alarmVariable of the RMON
alarmEntry while that alarmVariable is being sampled, the switch might reset. This problem is
resolved in software release 5.3(1a)CSX. (CSCdm49575)
TACACS cannot control access to the switch based on the host’s IP address. This problem is
resolved in software release 5.3(1a)CSX. (CSCdm60984)
A syslog message for a given facility is not sent to the syslog server if the syslog server severity
level is set to a value equal to or greater than the message severity but the default severity level
for that facility is set to a value less than the message severity. The workaround is to set the
default facility severity level to a value equal to or greater than the configured syslog severity
level. In release 5.3(1a)CSX, syslog messages are sent to the syslog server if the syslog server
severity level is equal to or greater than the message severity and the default facility severity level
is equal to or greater than the message severity. (CSCdm71889)
Open and Resolved Caveats in Software Release 5.2(3)CSX
This section describes open and resolved caveats in supervisor engine software release 5.2(3)CSX.
Open Caveats in Software Release 5.2(3)CSX
This section describes open caveats in supervisor engine software release 5.2(3)CSX:
Changing the console port baud rate from 19,200 to 38,400 incorrectly sets the console port to
9600 baud. After a reset, the console port baud rate is 38,400. Changing the rate to 38,400 from
any other setting works correctly. (CSCdk86876)
In systems with redundant supervisor engines, occasionally during bootup or after a switchover
to the redundant supervisor engine, a bus ASIC sequence error syslog message is reported to the
console as follows:
%SYS-1-MOD_SEQMISMATCH:Bus asic sequence mismatch occurred on module 8
This message might be generated for some or all installed modules. Ignore this message.
(CSCdm01334)