Installation guide
Release Notes for Catalyst 6000 Family Software Release 5.x 23
Resolved Caveats in Software Release 5.3(1a)CSX
• If traffic is received through a port that has port security enabled before the port is in the
forwarding state, the port is shutdown. This problem is fixed in software release 5.3(1a)CSX.
(CSCdk73206)
• If the switch is in VTP client mode, entry of a copy device:filename config command may
generate messages about nonexistent VLANs. Wait until the show vlan command displays the
VLANs and then enter the copy command again. This problem is fixed in software release
5.3(1a)CSX. (CSCdm07337)
• In some cases, on a switch with both BackboneFast and UplinkFast enabled, the show spantree
mod_num/port_num output shows that a port is in forwarding mode, but in reality the port is in
listening mode. As a result, all data traffic received on the port is discarded. The workaround is
to disable and reenable the affected port. This problem is resolved in software release
5.3(1a)CSX. (CSCdm08504)
• password authentication (without TACACS) can be slow when DNS is enabled and DNS server
IP address is configured, but the DNS server is not reachable. The workaround is to disable DNS.
This problem is resolved in software release 5.3(1a)CSX. (CSCdm14239)
• A module may report “Unknown GBIC” in the type field when HP GBIC(1000BASE-SX
30-0759-01) is installed. This problem is resolved in software release 5.3(1a)CSX.
(CSCdm14762)
• Do not configure anymodule so that the number of GVRP-enabled ports, including the individual
physical ports in GVRP-enabled EtherChannels, times the number of VLANs on the module,
exceeds 720. This problem is fixed in software release 5.3(1a)CSX. (CSCdm18614;
CSCdm18380)
• The MSM is not supported as a SPAN source port. Configuring the MSM as a SPAN source port
generates a “Failed to configure source port” message. If you configure the MSM as a SPAN
source port, all subsequent SPAN source port configuration commands for that SPAN session
generate the same message until you remove the MSM from the source port list with a set span
disable mod_num/port_num command. This problem is fixed in software release 5.3(1a)CSX.
(CSCdm20365)
• When you turn off the power on any module, you cannot turn the power back on through SNMP.
The workaround is to use the CLI command set module power up mod_num. This problem is
fixed in software release 5.3(1a)CSX. (CSCdm23288)
• In some cases, when the active link of an UplinkFast link pair is disconnected, the switch does
not transmit broadcast frames on the secondary link. This problem is resolved in software release
5.3(1a)CSX. (CSCdm23587)
• Occasionally, the switch shuts down in response to an erroneous over-temperature reading. This
problem is resolved in software release 5.3(1a)CSX. (CSCdm24976)
• In some cases, if the primary UplinkFast link goes down, when it comes back up it can take 20
to 25 seconds to begin forwarding traffic instead of the usual one to five seconds, depending on
the remote hardware. The workaround is to connect to a different port on the remote device if the
problem occurs. This problem is resolved in software release 5.3(1a)CSX. (CSCdm26273)
• In some cases, UplinkFast might not function correctly between a Catalyst 6000 family switch
and a Catalyst 4000 family switch, a Catalyst 2948G switch, or a Catalyst 5000 family Gigabit
EtherChannel module (WS-X5410). This problem is resolved in software release 5.3(1a)CSX.
(CSCdm34341)