Release Notes for Catalyst 6000 Family Software Release 5.x 21
Open and Resolved Caveats in Software Release 5.3(1a)CSX
ATM-related bug: In a configuration of about 150 VLANs and with a lot of unresolved ARPs on
the ATM module, the supervisor engine complains about the SCP queue being full. This problem
is resolved in software release 5.3(2)CSX. (CSCdp05776)
ATM-related bug: The ports of the ATM singlemode fiber-optic module are not added to the
spanning tree. This problem is resolved in software release 5.3(2)CSX. (CSCdp06550)
Bus-error exception when a Layer 2 multicast entry is both a multicast protocol configured entry
and also a user configured entry. This exception might occur when the multicast protocol is trying
to delete the entry. This problem is resolved in software release 5.3(2)CSX. (CSCdp06796)
Memory leak might occur if entries were created in alarmTable. This problem is resolved in
software release 5.3(2)CSX. (CSCdp03309)
Addresses are not learned in some VLANs due to vlan-don’t-learn bit being unintentionally
enabled. This problem is resolved in software release 5.3(2)CSX. (CSCdp00634)
Open and Resolved Caveats in Software Release 5.3(1a)CSX
This section describes open and resolved caveats in supervisor engine software release 5.3(1a)CSX.
Open Caveats in Software Release 5.3(1a)CSX
This section describes open caveats in supervisor engine software release 5.3(1a)CSX:
Changing the console port baud rate from 19,200 to 38,400 incorrectly sets the console port to
9600 baud. After a reset, the console port baud rate is 38,400. Changing the rate to 38,400 from
any other setting works correctly. (CSCdk86876)
In systems with redundant supervisor engines, occasionally during bootup or after a switchover
to the redundant supervisor engine, a bus ASIC sequence error syslog message is reported to the
console as follows:
%SYS-1-MOD_SEQMISMATCH:Bus asic sequence mismatch occurred on module 8
Additionally, “CentauriInterrupt” and “perseus_intr_hdlr” syslog messages might be generated.
These messages might be generated for some or all installed modules. Ignore these messages.
(CSCdm01334)
Occasionally, removal or insertion of a module does not generate any SYSLOG messages.
(CSCdm63338)
The set spantree disable all and enable all commands take 3 to 5 minutes to complete if VTP
pruning is enabled. To avoid the delay, disable VTP pruning before entering the command, and
reenable it after the command is complete. (CSCdm78945)
If you enable or disable QoS before a module is reported as being online, diagnostics on some
ports on the module may fail. (CSCdm85315)
The following message should be displayed when you modify the QoS default IP ACL to use the
trust-cos ACE keyword:
Warning: ACL trust-cos should only be used with ports that are also configured with
port trust=trust-cos.
(CSCdm88257)