18 Release Notes for Catalyst 6000 Family Software Release 5.x
Open and Resolved Caveats in Software Release 5.3(3)CSX
When using TACACS+, if you open a telnet session to the switch and enter a username and close
the telnet session without entering a password, the TACACS+ session from the switch to the
TACACS+ server remains open. This problem is resolved in software release 5.3(3)CSX.
(CSCdp02341)
Avoid using Ctrl-C after entering the configure network command. Using Ctrl-C results in a
command half completed which leaves the switch in an unknown state for that feature. This
problem is resolved in software release 5.3(3)CSX. (CSCdm27473)
The switch has been booted with a configuration that includes a QoS IP ACL. You then disable
QoS, but when you issue a set qos bridged-microflow-policing command, the command
completes without warning that QoS is disabled. This problem seems to only occur if the bridged
packet microflow feature is already enabled.
A second problem is when you issue a show qos acl info command; the ACL is displayed without
a warning that QoS is disabled. This problem is resolved in software release 5.3(3)CSX.
(CSCdm85903)
SNMP traps might not be properly generated. This problem is resolved in software release
5.3(3)CSX. (CSCdm76987)
A system reset might occur when traces are enabled and you attempt to do a TFTP activity such
as downloading a configuration. This problem is resolved in software release 5.3(3)CSX.
(CSCdm83928)
A system reset might occur upon receiving invalid PVSTs and BPDU's on an EtherChannel. This
problem is resolved in software release 5.3(3)CSX. (CSCdp07549)
Packets are still classified with old DSCP value after the ACL has been updated. This problem is
resolved in software release 5.3(3)CSX. (CSCdp10614)
The system might reset when you try to set objects in ciscoFlashPartitioningTable. This problem
has been fixed by not supporting this Table. This problem is resolved in software release
5.3(3)CSX. (CSCdp11615)
SNMP: After you set rowStatus of an eventEntry to under_creation, any set/get the eventEntry
might reset the system. This problem is resolved in software release 5.3(3)CSX. (CSCdp13317)
Occasionally after system power up, display shows minor hardware problem for modules. This
problem is resolved in software release 5.3(3)CSX. (CSCdp11646)
After entering a set boot config-register ignore-config and resetting the switch, the switch
comes back up and attempts to use BOOTP to obtain an IP address. When the BOOTP sending
messages are printed to the console, they are followed by a message: bootp_send: sendto 51. This
message indicates that the BOOTP send is failing. This problem is resolved in software release
5.3(3)CSX. (CSCdp19611)
If you change port speed from 100Mbps to 10Mbps and then back to 100Mbps, port traffic might
stop until you reset the module. This problem is resolved in software release 5.3(3)CSX.
(CSCdp11730)
A VTP client and a VTP server in the same VTP domain are separated by a VTP transparent
mode switch that is not a member of any VTP domain. When the VTP client is reset, the client
does not update its configuration after receiving a VTP update from the VTP server. This problem
is resolved in software release 5.3(3)CSX. (CSCdp05027)
VTP notifications are sent on wrong SCP SAP address for the ATM module. This problem is
resolved in software release 5.3(3)CSX. (CSCdp24165)