Installation guide

Chapter 2 Preparing for Installation
Determining Cable Distances
2-14
Catalyst 6500 Series Switch Module Installation Guide
78-15725-02
Table 2-10 lists the maximum transmission distances for console port cables.
See Appendix A, “Technical Specifications” for console port and cable pinout
information.
Port Connector Requirements—Switching Modules Only
You need these connector types to cable to the switching ports:
SC connectors for GBICs. (See Figure 2-4.)
Note When you plug the SC connector into the GBIC, make sure that both
the Tx and Rx fiber-optic cables are fully inserted into the SC
connector.
Note If you are using the LX/LH GBIC with MMF, you need to install a
patch cord between the GBIC and the MMF cable. See the “Patch
Cord” section on page 2-9 for details.
RJ-45 male connectors for the 48-port 10/100BASE-T RJ-45 module. (See
Figure 2-5.)
Table 2-10 EIA/TIA-232 Transmission Speed Versus Distance
Rate (bps) Distance (feet) Distance (meters)
2400 200 60
4800 100 30
9600 50 15
19,200 25 7.6
38,400 12 3.7
56,000 8.6 2.6