Specifications

4-16
Catalyst 6500 Series Switch and Cisco 7600 Series Router Network Analysis Module Installation and Configuration Note
78-16413-01
Chapter 4 Administering the Network Analysis Module
Catalyst Operating System Software
This example shows how to reset the module to the maintenance image from the enable mode:
Console> (enable) reset <module #> cf:1
This example shows how to reset the module to the NAM application image from the enable mode:
Console> (enable) reset <module #>
This example shows how to reset the NAM that is installed in slot 4 from the CLI:
Console> (enable) reset 4
This command will reset module 4.
Unsaved configuration on module 4 will be lost
Do you want to continue (y/n) [n]? y
ResetPcBlade:start shutdown module 4
SendShutDownMsg - proc_id (1):shut down PC success.
Module 4 shut down in progress, please don't remove module until shutdown comple
ted.
Module 4 is online.
You can enable a full memory test when you use the set boot device bootseq mod# mem-test-full
command. This option is disabled by default. This example shows how to do a full memory test:
Console (enable) set boot device cf:1
4
mem-test-full
Device BOOT variable = cf:1
Memory-test set to FULL
Warning:Device list is not verified but still set in the boot string.
Console> (enable) show boot device 4
Device BOOT variable = cf:1
Memory-test set to FULL
When you next reset the NAM, the full memory test runs. A full memory test takes more time to complete
than a partial memory test.
This example shows how to reset the partial memory test:
Console> (enable) set boot device cf:1 4
Device BOOT variable = cf:1
Memory-test set to PARTIAL
Warning:Device list is not verified but still set in the boot string.
Console> (enable)
Console> (enable) show boot device 4
Device BOOT variable = cf:1
Memory-test set to PARTIAL
Upgrading the NAM Software with Catalyst Operating System Software
You can upgrade both the application software and the maintenance software. To upgrade the application
software, see the “Upgrading the NAM Application Software with Catalyst Operating System Software”
section on page 4-17. To upgrade the maintenance software, see the “Upgrading the NAM Maintenance
Software with Catalyst Operating System Software” section on page 4-18.