Specifications

4-8
Catalyst 6500 Series Switch and Cisco 7600 Series Router Network Analysis Module Installation and Configuration Note
78-16413-01
Chapter 4 Administering the Network Analysis Module
Cisco IOS Software
SendShutDownMsg - proc_id (1):shut down PC success.
Module 4 shut down in progress, please don't remove module until shutdown completed.
Console> (enable) 2004 May 07 23:19:03 %SYS-5-MOD_OK:Module 4 is online
Upgrading the NAM Maintenance Software with Cisco IOS Software
To upgrade the NAM maintenance software, follow these steps:
Step 1 Copy the NAM maintenance software image to a directory accessible to FTP.
Step 2 Log in to the switch through the console port or through a Telnet session.
Step 3 If the NAM is running in the application image, go to Step 5. If the NAM is not running in the
application image, enter this command in the privileged mode:
Router# hw-module module 9 reset hdd:1
Device BOOT variable for reset = hdd:1
Warning:Device list is not verified.
Proceed with reload of module? [confirm]
% reset issued for module 9
Router#
00:31:11:%SNMP-5-MODULETRAP:Module 9 [Down] Trap
00:31:11:SP:The PC in slot 9 is shutting down. Please wait ...
00:31:25:SP:PC shutdown completed for module 9
00:31:25:%C6KPWR-SP-4-DISABLED:power to module in slot 9 set off (admin
request)
00:31:28:SP:Resetting module 9 ...
00:31:28:%C6KPWR-SP-4-ENABLED:power to module in slot 9 set on
00:33:26:%SNMP-5-MODULETRAP:Module 9 [Up] Trap
00:33:26:%DIAG-SP-6-BYPASS:Module 9:Online Diagnostics is Bypassed
00:33:26:%OIR-SP-6-INSCARD:Card inserted in slot 9, interfaces are now
online
Step 4 After the NAM is back online, establish a console session with the NAM and log in to the root account.
Step 5 Upgrade the NAM maintenance software as follows:
root@localhost# upgrade
ftp-url
where ftp-url is the FTP location and name of the NAM software image file.
Note If the FTP server does not allow anonymous users, use the following syntax for the ftp-url value:
ftp://user@host/absolute-path/filename. Enter your password when prompted.
Step 6 Follow the screen prompts during the upgrade.
Step 7 After completing the upgrade, log out of the NAM.
Step 8 Boot into the maintenance image with this command to reset the NAM maintenance software:
Router# hw-module module 9 reset cf:1
Device BOOT variable for reset = cf:1
Warning:Device list is not verified.
Proceed with reload of module? [confirm]
% reset issued for module 9
Router#
00:16:06:%SNMP-5-MODULETRAP:Module 9 [Down] Trap