Specifications
3-8
Catalyst 6500 Series Switch and Cisco 7600 Series Router Network Analysis Module Installation and Configuration Note
78-16413-01
Chapter 3 Getting Started
Configuring Traffic Sources for Capturing NAM Traffic
If the NetFlow device supports NDE version 8 aggregations, flows from one or more of the version 8
aggregation caches may be exported to the NAM. To export flows from the aggregation caches, perform
these steps:
Step 1 Select an NDE version 8 aggregation.
Router(config)# ip flow-aggregation cache
aggregation-type
The supported aggregation types are as follows:
• Destination-prefix
• Source-prefix
• Protocol-port
• Prefix
Step 2 Enable the aggregation cache.
Router(config-flow-cache)# enable
Step 3 Export the flow entries in the aggregation cache to NAM UDP port 3000.
Router(config-flow-cache)# export destination
NAM-Address
3000
Step 4 Verify NDE.
Router# show ip cache flow-aggregation
aggregation-type
This example shows how to set up an NDE version 8 aggregation configuration:
Router(config)# ip flow-aggregation cache prefix
Router(config-flow-cache)# enable
Router(config-flow-cache)# export destination 172.20.104.74 3000
Router(config-flow-cache)# exit
Router(config)# show ip cache flow-aggregation prefix
Catalyst Operating System Software
You can capture traffic for NAM monitoring from a single VLAN or from multiple VLANs. If you want
to monitor traffic from specific VLANs only, you need to clear the VLANs that you do not want to
monitor from the capture feature.
Using SPAN as a Traffic Source
You can configure Remote SPAN (SPAN) as a traffic source using both the NAM Traffic Analyzer
application and the switch CLI. We recommend that you use NAM Traffic Analyzer.
For more information about SPAN and RSPAN, refer to the “Configuring SPAN and RSPAN” chapter in
the Catalyst 6500 Series Switch Software Configuration Guide.
You can use RSPAN traffic as a SPAN source for the NAM. Verify that the SPAN source is set to the
same VLAN ID that is used for RSPAN. The SPAN destination should be set to nam_module/port.