Release Notes for Catalyst 6500 Series Content Switching Module Software Release 2.2(8)
78-12569-16
Troubleshooting
Error Message SLB-LCSC: DFP agent <x> disabled server <x>, protocol <x>, port <x>
Explanation
The configured DFP agent has reported a weight of 0 for the specified real server.
Error Message SLB-LCSC: DFP agent <x> re-enabled server <x>, protocol <x>, port <x>
Explanation
The configured DFP agent has reported a non-zero weight for the specified real server.
Diagnostic Messages
Error Message SLB-DIAG: WatchDog task not responding.
Explanation
A critical error occurred within the CSM hardware or software.
Error Message SLB-DIAG: Fatal Diagnostic Error %x, Info %x.
Explanation
A hardware fault was detected. The hardware is unusable and must be repaired or
replaced.
Error Message SLB-DIAG: Diagnostic Warning %x, Info %x.
Explanation
A non-fatal hardware fault was detected.
Fault-Tolerance Messages
Error Message SLB-FT: No response from peer. Transitioning from Standby to Active.
Explanation
The CSM detected a failure in its fault-tolerant peer and has transitioned to the active
state.
Error Message SLB-FT: Heartbeat intervals are not identical between ft pair.
SLB-FT: Standby is not monitoring active now.
Explanation Proper configuration of the fault-tolerance feature requires that the heartbeat intervals be
identical between CSMs within the same fault-tolerance group, and this is currently not the case. The
fault-tolerance feature is disabled until the heartbeat intervals have been configured identically.