User manual

17
Release Notes for Catalyst 6500 Series Content Switching Module Software Release 2.2(8)
78-12569-16
Caveats
Traffic into the CSM from an IP address must arrive on the same VLAN that the CSM uses to
send to that IP address. Ensure that all traffic received by the CSM from a specific destination
address arrives on the same VLAN that the CSM uses to reach that destination if the CSM is
configured with a route as follows:
Router(config)# module csm 4
Router(config-module-csm)# vlan 10 client
Router(config-slb-vlan-client)# route 10.0.0.0 255.255.255.0 gateway 1.1.1.1
For load balancing to function properly, all traffic arriving from the 10.0.0.0/24 subnet must
reach the CSM through VLAN 10.
Resolved Caveats in Release 2.2(7)
This section describes caveats that have been resolved in CSM software release 2.2(7).
CSCdz48294
When a VLAN interface is removed from the CSM configuration, the learned ARP entries
associated with this subnet are still in the ARP table of CSM.
Workaround: None.
CSCdz47531
In the 2.2(7) release, the CSM now supports non-standard HTTP requests from the Wireless
Application Protocol (WAP) devices.
Workaround: None.
CSCdz38938
When one of the firewalls fails ARP request, the ICMP health probe to other servers or firewalls will
occasionally drop the ICMP reply. If the number of probe attempts is small, other ICMP health
probes could incorrectly be marked as failed.
Workaround: Increase the probe retries count, and increase the probe failed interval for ICMP.
CSCdz35004
The CSM receive engine was limiting the ICMP probe rate to 60 probes per second. With the fix in
the 2.2(7) release, the maximum ICMP health probe rate is at 600 probes per second.
Workaround: None.
CSCdz34419
When you configure a virtual server with a wildcard 0.0.0.0 address, and you use the clear module
csm id conns vserver vs-name command, the command clears all current opened connections in the
CSM.
Workaround: None.
CSCdz24949
The clear module csm x arp command does not clear the learned ARP entries.
Workaround: Any old learned ARP entries are removed in the next ARP probing cycle.
CSCdy04751
Sometimes the CSM cannot get the fault tolerance statistics from the hardware. In this case, the
show module csm x ft command always returns an error. However, the fault tolerance function is
still working.