Installation guide
13
Cisco Catalyst 6500 Series Application-Oriented Networking Module Installation Note
78-16749-01
Installing the Module
Step 3 Verify that the captive installation screws are tightened on all modules installed in the chassis.
This action ensures that the EMI gaskets on all modules are fully compressed to maximize the opening
space for the replacement module.
Note If the captive installation screws are loose, the EMI gaskets on the installed modules will push
adjacent modules toward the open slot, reducing the opening size and making it difficult to
install the replacement module.
Step 4 Remove the module filler panel by removing the two Phillips pan-head screws from the filler panel. (To
remove a module, refer to the “Removing the Module” section on page 11.)
Step 5 Fully open both ejector levers on the new or replacement module. (See Figure 2.)