Installation guide
67
Release Notes for Catalyst5000 Family Software Release4.x
OL-2306-01
Open and Resolved Caveats in Software Release4.2(1)
• In certain cases, if there are multiple ports assigned to the same TrCRF VLAN on different modules
in a Catalyst 5000 family switch, and an ATM LAN emulation client (LEC) is one of those ports,
Token Ring source-route switching might not forward data correctly.
Workaround: Disable the spanning tree for the parent TrBRF VLAN (using the set spantree
disable vlan_num command) and then reenable the TrBRF spanning tree (using the set spantree
enable vlan_num command). This problem is resolved in software release4.2(2). (CSCdk48854)
• In some cases, in a redundant supervisor engine configuration, communication between the two
supervisor engine modules might be lost when a broadcast storm occurs.
Workaround: Reset the switch. This problem is resolved in software release4.2(2). (CSCdk38130)
• In some cases, when a parity error occurs, the switch might reset without first validating the parity
error in hardware. This problem is resolved in software release4.2(2). (CSCdk47791)
• In some cases, configuring multiple default gateways on a Catalyst 5000 family switch can result in
poor performance over time (due to progressively reduced available memory).
Workaround: Remove non-primary gateways from the configuration using the clear ip route
default gateway command and reset the switch. This problem is resolved in software release4.2(2).
(CSCdk46384)
Open and Resolved Caveats in Software Release4.2(1)
These sections describe the open and resolved caveats in supervisor engine software release4.2(1):
• Open Caveats in Software Release4.2(1), page67
• Resolved Caveats in Software Release4.2(1), page69
Open Caveats in Software Release4.2(1)
Note For a description of caveats resolved in software release 4.2(1), see the “Resolved Caveats in
Software Release4.2(1)” section on page69.
This section describes open caveats in software release4.2(1).
• On the Gigabit EtherChannel module (WS-X5410), if a host allowed on one secured port is moved
to another, previously unused secured port on the same module, the host cannot connect to the
network on the second port.
Workaround: Disable port security on the first port, move the host to the second port, and then
reenable port security on the first port (if desired). (CSCdk31747)
• On the Gigabit EtherChannel module (WS-X5410), when the native VLAN of a trunk port is cleared
and then the trunk port is set to off, the port is placed in the inactive state but the Link LED for the
port still shows green. The correct behavior is that the LED for the port should show orange.
(CSCdk31985)
• In the “Designated Root Port” field of the show spantree command, a four-port channel on
ports4–8 of the Gigabit EtherChannel module (WS-X5410) is incorrectly shown as being a
five-port channel (ports5–9). (CSCdk25123)