Open and Resolved Caveats in Software Release 4.5(6)
This section describes caveats resolved in software release 4.5(6):
If a large number of RMON history, alarm, and event entries are continuously deleted and added,
the RMON alarmTimer experiences a memory allocation problem. This problem is resolved in
software release 4.5(6). (CSCdp58575)
When a FDDI port is trunking, a fast link flap may cause the port to stop trunking. This problem is
resolved in software release 4.5(6). (CSCdp72267)
Supervisor Engine III experiences an exception when receiving an rmon_set_historyEnable entry.
This problem is resolved in software release 4.5(6). (CSCdp67262)
A port status mismatch might occur on Catalyst 5000 family switch module WS-X5225R and
WS-X5234 ports that are directly connected to ports on the WS-X6248-RJ-45 Catalyst 6000 family
switch module. This problem is resolved in software release 4.5(6). (CSCdp61755)
If you define VLAN groups in the VMPS configuration database file, there may not be enough free
memory to save this information. This problem is resolved in software release 4.5(6).
(CSCdp68303)
TACACS+ might experience an exception if access to an invalid socket is attempted. This problem
is resolved in software release 4.5(6). (CSCdp40197)
With the Catalyst 5000 family switch running software release 4.5(1) and later, the ifOutUcastPkts
and ifInUcastPkts counter sometimes decrements instead of increments on 10/100 Ethernet ports.
This problem is resolved in software release 4.5(6). (CSCdp71615)
If you configure a Catalyst 5000 family switch for VTP client mode with redundant Supervisor
Engine IIIGs (WS-X5550s), there is no connectivity to devices on the WS-X5101 after the switch
reloads. This problem is resolved in software release 4.5(6). (CSCdp68378)
Intermittently, PVST+ conversion is not performed when BPDUs go from a non-native VLAN on
an 802.1Q trunk to an access port and STP is disabled. This problem is resolved in software release
4.5(6). (CSCdp81050)
If a port comes up as an individual port and there is a channel in its EBC range, the port gets the
default channel port setting whether the port is connected or not. From the point of view of a Fast
Ethernet channel, the switch appears to be sending traffic through a disconnected port.This problem
is resolved in software release 4.5(6). (CSCdp78923)
Supervisor Engine II in a Catalyst 5500 running software version 4.5(5) will continually reboot.
This problem is resolved in software release 4.5(6). (CSCdp74698)
TrafficDirector NetFlow monitoring stops on the Network Analysis module (WS-X5380) after the
module is reset. This problem is resolved in software release 4.5(6). (CSCdp10760)
Entering the show mls command after changing the flowmask from destination to full can cause a
system exception. This problem is resolved in software release 4.5(6). (CSCdp02406)
When using VMPS on ports connected to routers running HSRP that are not configured to use the
burned-in address, the Catalyst 5000 family switch might reset when the active HSRP router is shut
down.
Workaround: Configure standby use-bia on the router interfaces for the HSRP (standby uses the
interfaces burned in address [bia]). This problem is resolved in software release 4.5(6).
(CSCdp51787)
Occasionally, when MLS detects a host move, the show mls entry command might display no
entries. This problem is resolved in software release 4.5(6). (CSCdp39218)
VTP updates received through other trunks might enable disabled trunks that have a default VLAN
other than 1. This problem is resolved in software release 4.5(6). (CSCdp39638)