Release Notes for Catalyst5000 Family Software Release4.x
OL-2306-01
Open and Resolved Caveats in Software Release 4.5(10)
Open and Resolved Caveats in Software Release 4.5(10)
This section describes open and resolved caveats in supervisor engine software release4.5(10):
• Open Caveats in Software Release4.5(10), page24
• Resolved Caveats in Software Release4.5(10), page24
Open Caveats in Software Release4.5(10)
Note For a description of caveats resolved in software release4.5(10), see the “Resolved Caveats in
Software Release4.5(10)” section on page24.
This section describes open caveats in software release4.5(10).
• If you have multiple ATM fabric integration modules (WS-X5165) installed and you have more than
50 LECs configured on each module, a multiple-module software download to the modules can take
an excessively long time to complete. For this reason, we recommend that you download software
images one module at a time (by specifying the module number in the download command).
(CSCdk55355)
• On the Gigabit EtherChannel module (WS-X5410), if a host allowed on one secured port is moved
to another previously unused secured port on the same module, the host cannot connect to the
network on the second port.
Workaround: Disable port security on the first port, move the host to the second port, and then
reenable port security on the first port (if desired). (CSCdk31747)
• After a switchover from the active to the standby supervisor engine, the SPAN destination port
might not function correctly. (CSCdk55360)
Resolved Caveats in Software Release4.5(10)
Note For a description of open caveats in software release4.5(10), see the “Open Caveats in Software
Release4.5(10)” section on page24.
This section describes caveats resolved in software release 4.5(10):
• A series of unauthenticated Telnet attempts can cause the switch to fail to pass traffic or accept
management connections until the system is rebooted or a power cycle is performed. This problem
is resolved in software release 4.5(10). (CSCds66191)
• Supervisor engine might not respond to SNMP queries. In a Catalyst 5000 family switch with the
WS-X5530 supervisor engine and the WS-X5012 10BASE-T module, SCP communication between
the supervisor engine and the WS-X5012 module might fail. The SNMP is unable to collect statistics
from the switching module and SNMP stops responding to queries. This problem is resolved in
software release 4.5(10). (CSCds16761)
• Non-alphanumeric characters are not valid in VTP domain names but can be configured in certain
cases. This problem is resolved in software release 4.5(10). (CSCds34927)