Release Notes for Catalyst5000 Family Software Release4.x
OL-2306-01
Open and Resolved Caveats in Software Release 4.5(11)
The reset is caused by a high number of MLS-enabled interfaces with HSRP and static MAC
addresses configured. The fix allows MLS to be enabled on a large number of interfaces configured
for MLS.
This problem is resolved in software release 4.5(12). (CSCdp08252)
Note that the RSM IOS software must be upgraded to 12.2(1) or later.
When the ifOperStatus value for the port changes (the port is enabled and disabled, or the link is
brought up and down), the ifLastChange value for the port does not change.
This problem is resolved in software release 4.5(12). (CSCdt69418)
The switch might reset with a TLB exception when CmpOctetStringWithLen() receives a null
pointer.
This problem is resolved in software release 4.5(12). (CSCdt75849)
Open and Resolved Caveats in Software Release 4.5(11)
This section describes open and resolved caveats in supervisor engine software release4.5(11):
Open Caveats in Software Release4.5(11), page22
Resolved Caveats in Software Release4.5(11), page23
Open Caveats in Software Release4.5(11)
Note For a description of caveats resolved in software release4.5(11), see the Resolved Caveats in
Software Release4.5(11)” section on page23.
This section describes open caveats in software release4.5(11).
On Catalyst 5500 series switches, Gigabit Ethernet autonegotiation is broken on the Gigabit
Ethernet uplink module (WS-U5534) in supervisor engine software releases 4.5(11), 4.5(12), and
4.5(13). Autonegotiation fails only if the other end of the link is also connected to a WS-U5534
uplink module. There is no problem if the other end of the link is connected to another Gigabit
Ethernet module such as the 3- or 9-port modules.
Turning off autonegotiation to avoid the problem is not recommended as this can lead to
spanning-tree loops if you have a unidirectional link. The only workaround is to connect a WS-U5534
uplink module to a different module (not the WS-U5534 uplink module). (CSCdw21589)
If you have multiple ATM fabric integration modules (WS-X5165) installed and you have more than
50 LECs configured on each module, a multiple-module software download to the modules can take
an excessively long time to complete. For this reason, we recommend that you download software
images one module at a time (by specifying the module number in the download command).
(CSCdk55355)