Release Notes for Catalyst5000 Family Software Release4.x
OL-2306-01
Open and Resolved Caveats in Software Release 4.5(12)
Open and Resolved Caveats in Software Release 4.5(12)
This section describes open and resolved caveats in supervisor engine software release4.5(12):
Open Caveats in Software Release4.5(12), page20
Resolved Caveats in Software Release4.5(12), page21
Open Caveats in Software Release4.5(12)
Note For a description of caveats resolved in software release4.5(12), see the Resolved Caveats in
Software Release4.5(12)” section on page21.
This section describes open caveats in software release4.5(12).
On Catalyst 5500 series switches, Gigabit Ethernet autonegotiation is broken on the Gigabit
Ethernet uplink module (WS-U5534) in supervisor engine software releases 4.5(11), 4.5(12), and
4.5(13). Autonegotiation fails only if the other end of the link is also connected to a WS-U5534
uplink module. There is no problem if the other end of the link is connected to another Gigabit
Ethernet module such as the 3- or 9-port modules.
Turning off autonegotiation to avoid the problem is not recommended as this can lead to
spanning-tree loops if you have a unidirectional link. The only workaround is to connect a WS-U5534
uplink module to a different module (not the WS-U5534 uplink module). (CSCdw21589)
If you have multiple ATM fabric integration modules (WS-X5165) installed and you have more than
50 LECs configured on each module, a multiple-module software download to the modules can take
an excessively long time to complete. For this reason, we recommend that you download software
images one module at a time (by specifying the module number in the download command).
(CSCdk55355)
If IGMP snooping or CGMP is disabled while protocol filtering is enabled, Layer 2 multicast
forwarding will be affected when protocol filtering is later disabled. The commands to reproduce
this are:
a. set igmp enable (or set cgmp enable)
b. set protocolfilter enable
c. set igmp disable (or set cgmp disable)
d. set protocolfilter disable
Workaround: Reenable protocol filtering, which will restore multicast traffic forwarding. If you
do not want to reenable protocol filtering, you must reset the switch to resolve the condition.
(CSCdu04672)
On the Gigabit EtherChannel module (WS-X5410), if a host allowed on one secured port is moved
to another previously unused secured port on the same module, the host cannot connect to the
network on the second port.
Workaround: Disable port security on the first port, move the host to the second port, and then
reenable port security on the first port (if desired). (CSCdk31747)
After a switchover from the active to the standby supervisor engine, the SPAN destination port
might not function correctly. (CSCdk55360)