Number of
802.3af Class
2 Power Devices
Supported with
1 Power Supply
(1+1)
102 178
●
384 PDs
(200V)
●
241 PDs
(100V)
384 384
Number of
802.3af Class 0
and 3 Power
Devices
Supported with
1 Power Supply
(1+1)
46 80
●
222 PDs
(200V)
●
109 PDs
(100V)
384 384
Hot Swappable Yes Yes Yes Yes Yes
Additional notes for Table 7 and 8:
1. Output power is per power supply, unless otherwise stated.
2. Heat dissipation numbers represent the power-conversion losses of the power supply in
operation.
3. The number of power devices supported will depend on customer configuration.
Fan Trays
Each Cisco Catalyst 4500-E Series and Classic Catalyst 4500 chassis uses a single fan tray for
cooling. All fan trays are composed of independent fans. If one fan fails, the system will continue to
operate without a significant degradation in cooling. The system will detect and notify the user
(through LED, command-line interface [CLI], and SNMP) that a fan has failed and the tray needs to
be replaced. Catalyst 4500-E Series Fans cannot be interchanged with Classic Catalyst 4500
Series Fans.
Fabric-Redundancy Modules (Cisco WS-C4507R-E, WS-C4510R-E, WS-C4507R,
WS-C4510R Only)
The Cisco Catalyst 4500-E and Classic Catalyst 4500 Series redundancy scheme uses removable
fabric-redundancy modules on the passive backplane to switch traffic to the active supervisor
engine. There is one fabric-redundancy module per line card. Fabric-redundancy modules and
redundant clocks ship standard with every Cisco Catalyst 4507R,-E 4507R and 4510R-E and
4510R chassis. Fabric redundancy modules cannot be interchanged between the Catalyst 4500-E
and Classic Catalyst 4500 Chassis Spare fabric-redundancy modules and clock modules are
available for serviceability.
Environmental Conditions
The Cisco Catalyst 4500-E and Classic Catalyst 4500 Series requires the following conditions:
●
Operating temperature: 32 to 104ºF (0 to 40ºC)
●
Storage temperature: –40 to 167ºF (–40 to 75ºC)
●
Relative humidity: 10 to 90 percent, noncondensing
●
Operating altitude: –60 to 2000 meters (m)
Regulatory Standards Compliance
Table 9 lists the regulatory standards compliance of the Cisco Catalyst 4500-E and Classic 4500