Datasheet

© 2012-2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 32 of 35
Heat Dissipation Cisco XPS 2200 Power Supply Configuration
No Load (BTU/hr) Full Load (BTU/hr)
2 x 1100WAC 205 1350
1 x 440WDC 115 645
2 x 440WDC 155 990
Physical and Environmental Specifications
Table 23 lists the physical and environmental specifications for XPS-2200.
Table 23. Physical and Environmental Specifications
Description Specification
Physical specifications H x W x D:
1.73 x 17.5 x 20.5 in.
(4.4 x 44.5 x 52.1 cm)
Weight:
19.8 lb (9.0 kg)
Total input BTU (1000 BTU/Hr = 290W) 8525 BTU/Hr
Operating temperature -5 to 45°C up to 5000ft elevation, -5 to 4C up to 10000ft elevation
Storage temperature -40 to 70°C
Relative humidity operating, non-
condensing
5 to 95% non-condensing
Relative humidity non-operating, non-
condensing
5 to 95% non-condensing
Operating altitude 10,000 ft. (3000m)
Storage altitude 15,000 ft. (4750 m)
Mean Time Between Failure (MTBF) 222,000 hours
Electromagnetic compatibility certifications FCC Class A for North America: 47 CFR Part 15
VCCI Class A for Japan: V-3/2007.04
CCC EMC for China on Spare Power Supplies: EN61000-3-2 (GB17625.1-1998)
BSMI Class A for Taiwan: CNS13438
KCC (formerly MIC) GB17625.1-1998 Class A for Korea: KN24/KN22
AS/NZS Class A for Australia: CISPR22:2004 or EN55022
Brazil, ANATEL In-Country approval
CE Class A for European Union: EN55022, EN300386, EN55024 (CISPR24)
Safety certifications UL 60950-1
CAN/CSA 22.2 No.60950-1
EN 60950-1CB to IEC 60950-1
GB 4943
Acoustic Specifications
Table 24 lists the acoustic specifications of the Cisco XPS 2200.
The following numbers represent the range of values for Idle, 50% and 100%:
Table 24. Cisco XPS 2200 Acoustic Specifications
Sound Pressure Sound Power Cisco XPS 2200 Power Supply Configuration
LpA (Typical) LpAD (Maximum) LwA (Typical) LwAD (Maximum)
2 x 1100WAC 43 dB 63 dB 5.3 B 7.3 B
2 x 715WAC 42 dB 61 dB 5.3 B 6.6 B