© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 13 of 20
Power Connectors
●
Customers can provide power to a switch by using either the internal power supply or the Cisco RPS 2300. The
connectors are located at the back of the switch.
Internal-Power-Supply Connector
●
The internal power supply is an autoranging unit.
●
The internal power supply supports input voltages between 100 and 240 VAC.
●
Use the supplied AC power cord to connect the AC power connector to an AC power outlet.
●
Cisco RPS Connector
●
The connector offers connection for an optional Cisco RPS 2300 (model PWR-RPS2300) that uses AC input and
supplies DC output to the switch.
Indicators
●
Per-port status LEDs: Link integrity, disabled, activity, speed, full-duplex indications, PoE applied, PoE error, and
PoE disabled indications
●
System-status LEDs: System, RPS, link status, link duplex, link speed, and PoE indications
Inches Centimeters
3560V2-24TS 1.73 x 17.46x 11.62 4.4 x 44.3 x 29.5
3560V2-48TS 1.73 x 17.46x 11.62 4.4 x 44.3 x 29.5
3560V2-24PS 1.73 x 17.46x 11.62 4.4 x 44.3 x 29.5
3560V2-48PS 1.73 x 17.46x 11.62 4.4 x 44.3 x 29.5
Dimensions
(H x W x D)
3560V2-24DC 1.73 x 17.46x 11.62 4.4 x 44.3 x 29.5
Pounds Kilograms
3560V2-24TS 8.2 3.7
3560V2-48TS 9 4
3560V2-24PS 10 4.6
3560V2-48PS 11 5
Weight
3560V2-24DC 8 3.7
Fahrenheit Centigrade
Operating temperature 32 to 113ºF 0 to 45ºC
Storage temperature -13 to 158ºF -25 to 70ºC
Feet Meters
Operating altitude Up to 9,843 ft Up to 3,000 m
Storage altitude Up to 15,000 ft Up to 4,573 m
Operating relative humidity 10 to 85% noncondensing
Environmental Ranges
Storage relative humidity 10 to 85% noncondensing
ISO 7779 & ISO 9296: Bystander positions operating to an ambient temperature of 25°C
Sound Pressure Sound Power
LpA
(Typical)
LpAD
(Maximum)
LwA
(Typical)
LwAD
(Maximum)
3560V2-24TS 41 dB 44 dB 5.1 B 5.4 B
3560V2-48TS 42 dB 45 dB 5.2 B 5.5 B
3560V2-24PS 44 dB 47 dB 5.5 B 5.7 B
3560V2-48PS 45 dB 48 dB 5.5 B 5.8 B
3560V2-24DC 41 dB 44 dB 5.2 B 5.5 B
Acoustic Noise
Typical: Noise emission for a typical configuration and load at 25° C
Maximum: Statistical maximum to account for variation in production
3560V2-24TS 377,260 hours
3560V2-48TS 301,886 hours
3560V2-24PS 275,360 hours
3560V2-48PS 206,041 hours
Mean Time Between
Failure (MTBF)
3560V2-24DC 451,606 hours