Datasheet
Data Sheet
All contents are Copyright © 1992–2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 16 of 23
Table 6 lists the specifications of all the power supplies supported in Cisco Catalyst 3560-E Series
Switches.
Table 6. Power Supply Specifications
Power Supply Product Specifications
C3K-PWR-
1150WAC
C3K-PWR-
750WAC
C3K-PWR-
265WAC
C3K-PWR-
265WDC
C3K-PWR-
300WAC
C3K-PWR-
300WDC
Physical Specifications (H x W x D):
1.65 X 6.0 X
14.90 in
Weight: 5.6 lb
(2.6 kg)
(H x W x D):
1.65 X 6.0 X
11.4 in
Weight: 3.9 lb
(1.8 kg)
(H x W x D):
1.65 X 6.0 X
11.4 in
Weight: 3.3 lb
(1.5 kg)
(H x W x D):
1.65 X 6.0 X
11.4 in
Weight: 3.5 lb
(1.6 kg)
(H x W x D):
1.58 X 4.0 x 9.0 in
Weight: (2 Kg)
Total Output BTU (Note:
1000 BTU/hr = 290W)
3939 BTU/hr,
1150W
2568 BTU/hr,
765W
907 BTU/hr,
265W
907 BTU/hr,
265W
1034 BTU/hr, 300W
Operating Temperature 23 to 113°F (-5 to 45°C) 23 to 131°F (-5 to 55°C)
Storage Temperature -40 to 158°F (-40 to 70°C) -40 to 185°F (-40 to 85°C)
Relative Humidity
Operating,
10 to 85% noncondensing 10 to 90% noncondensing
Relative Humidity
Nonoperating,
0 to 95% noncondensing 5 to 95% noncondensing
Altitude 10,000 ft. (3000 meters), up to 45°C Operating: -500 to 10,000 ft.
(-152 to 3048 m) over allowable
temperature range
Nonoperating: -1,000 to 50,000
ft. (-304 to 15,240 m) over
allowable temperature range
MTBF Calculated MTBF must be greater than 300,000 hrs using
Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is
500,000 hrs (with 90% confidence level).
Calculated
MTBF 220,000
hrs with fan
(MIL HDBK
217F formula).
Demonstrated
MTBF 150,000
hrs with 90%
confidence.
Calculated
MTBF 662,000
hrs with fan
(Bellcore
formula).
Demonstrated
MTBF 150,000
hrs with 90%
confidence.
EMI and EMC
Compliance
●
FCC Part 15 (CFR 47) Class A
●
ICES-003 Class A
●
EN 55022 Class A
●
CISPR 22 Class A
●
AS/NZS 3548 Class A
●
VCCI Class A
●
EN 55024
●
EN300 386
●
EN 50082-1
●
EN 61000-3-2
●
EN 61000-3-3
●
EN 61000-6-1
NEBS Compliant (Except C3K-PWR-1150WAC and C3K-PWR-750WAC)
Safety Compliance
●
UL 60950-1 1st Edition
●
CAN/CSA-C22.2 No. 60950-1 1st Edition
●
EN 60950-1 1st Edition
●
IEC 60950-1 1st Edition
LED Indicators
●
“AC OK” or “DC IN”: Input power to the power supply is
OK.
●
“PS OK”: Output power from the power supply is OK.
●
“AC OK”: Input power to the
power supply is OK.
●
“PS OK”: Output power from
the power supply is OK.