© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 18 of 24
Altitude 10,000 ft. (3000 meters), up to 45°C Operating: -500 to 10,000 ft.
(-152 to 3048 m) over allowable
temperature range
Nonoperating: -1,000 to 50,000
ft. (-304 to 15,240 m) over
allowable temperature range
MTBF Calculated MTBF must be greater than 300,000 hrs using
Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is
500,000 hrs (with 90% confidence level).
Calculated
MTBF 220,000
hrs with fan
(MIL HDBK
217F formula).
Demonstrated
MTBF 150,000
hrs with 90%
confidence.
Calculated
MTBF 662,000
hrs with fan
(Bellcore
formula).
Demonstrated
MTBF 150,000
hrs with 90%
confidence.
EMI and EMC
Compliance
FCC Part 15 (CFR 47) Class A
ICES-003 Class A
EN 55022 Class A
CISPR 22 Class A
AS/NZS 3548 Class A
VCCI Class A
EN 55024
EN300 386
EN 50082-1
EN 61000-3-2
EN 61000-3-3
EN 61000-6-1
NEBS Compliant (Except C3K-PWR-1150WAC and C3K-PWR-750WAC)
Safety Compliance
UL 60950-1 1st Edition
CAN/CSA-C22.2 No. 60950-1 1st Edition
EN 60950-1 1st Edition
IEC 60950-1 1st Edition
LED Indicators
“AC OK” or “DC IN”: Input power to the power supply is
OK.
“PS OK”: Output power from the power supply is OK.
“AC OK”: Input power to the
power supply is OK.
“PS OK”: Output power from
the power supply is OK.
Table 7 lists the safety and compliance information for the Cisco Catalyst 3560-E Series.
Table 7. Safety and Compliance
Description Specification
Safety Certifications
UL60950-1
C-UL to CAN/CSA 22.2 No.60950-1
TUV/GS to EN 60950-1
CB to IEC 60950-1 with all country deviations
CE Marking
CCC for PS FRU
Electromagnetic Emissions
Certifications
FCC Part 15 Class A
EN 55022 Class A (CISPR22 Class A)
CNS13438 Class A (applicable only to FRU power supplies)
AS/NZS CISPR22 Class A
EN55024
GR-1089 CORE Class A
EN 300 368
MIC
CE Marking
China (applicable only to FRU power supplies)
NEBS
GR-63-CORE, GR-1089-CORE
Level 3 Type 2, 4 and Wall Mount
AT&T TP76200 Checklist
TCG NEBS Checklist