Installation guide

D-7
Catalyst 3550 Multilayer Switch Hardware Installation Guide
78-11358-06
Appendix D Configuring the Switch with the CLI-Based Setup Program
Entering the Initial Configuration Information
Step 6 (Optional) Configure SNMP by responding to the prompts. You can also
configure SNMP later through the CLI or CMS interface. To configure SNMP
later, enter no.
Configure SNMP Network Management? [no]: no
Step 7 Enter the interface name (physical interface or VLAN name) of the interface that
connects to the management network, and press Return. For this release, always
use vlan1 as that interface.
Enter interface name used to connect to the
management network from the above interface summary: vlan1
Step 8 Configure the interface by entering the switch IP address and subnet mask and
pressing Return. (The IP address and subnet masks shown here are examples.)
Configuring interface vlan1:
Configure IP on this interface? [yes]: yes
IP address for this interface: 10.4.120.106
Subnet mask for this interface [255.0.0.0]: 255.255.255.0
Step 9 Enter Y to configure the switch as the cluster command switch. Enter N to
configure it as a member switch or as a standalone switch.
If you enter N, the switch appears as a candidate switch in the CMS. You can
configure the switch as a command switch later through the CLI or CMS interface.
To configure it later, enter no.
Would you like to enable as a cluster command switch? [yes/no]: no
You have now completed the initial configuration of the switch, and the switch
displays its initial configuration. This is an example of the output that appears:
The following configuration command script was created:
hostname host-name
enable secret 5 $1$Ulq8$DlA/OiaEbl90WcBPd9cOn1
enable password enable_password
line vty 0 15
password terminal-password
no snmp-server
!
no ip routing
!
interface Vlan1
no shutdown
ip address 10.4.120.106 255.0.0.0
!