Datasheet

© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 9 of 13
Cisco Catalyst 2960-Plus 48TC-L 0.04
Cisco Catalyst 2960-Plus 24TC-L 0.03
Cisco Catalyst 2960-Plus 48PST-S 0.46
Cisco Catalyst 2960-Plus 24PC-S 0.43
Cisco Catalyst 2960-Plus 24LC-S 0.16
Cisco Catalyst 2960-Plus 48TC-S 0.04
Cisco Catalyst 2960-Plus 24TC-S 0.02
DC Input Voltages (RPS Input)
Cisco Catalyst 2960-Plus 48PST-L 3A at 12V 7A at -52V
Cisco Catalyst 2960-Plus 24PC-L 2A at 12V 7A at -52V
Cisco Catalyst 2960-Plus 24LC-L 2A at 12V 3A at -52V
Cisco Catalyst 2960-Plus 48TC-L 3A at 12V -
Cisco Catalyst 2960-Plus 24TC-L 2A at 12V -
Cisco Catalyst 2960-Plus 48PST-S 3A at 12V 7A at -52V
Cisco Catalyst 2960-Plus 24PC-S 2A at 12V 7A at -52V
Cisco Catalyst 2960-Plus 24LC-S 2A at 12V 3A at -52V
Cisco Catalyst 2960-Plus 48TC-S 3A at 12V -
Cisco Catalyst 2960-Plus 24TC-S 2A at 12V -
Table 10. Power Consumption
Measured Power Consumption, Watts
Model 0% traffic 10% traffic 100% traffic ATIS weighted average
Cisco Catalyst 2960-Plus 48PST-L 51.1 50.8 51.4 50.9
Cisco Catalyst 2960-Plus 24PC-L 35.4 35.3 35.6 35.3
Cisco Catalyst 2960-Plus 24LC-L 25.9 25.7 26.1 25.8
Cisco Catalyst 2960-Plus 48TC-L 30.4 30.2 30.6 30.2
Cisco Catalyst 2960-Plus 24TC-L 18.4 18.3 18.6 18.3
Cisco Catalyst 2960-Plus 48PST-S 50.8 50.3 51.1 50.5
Cisco Catalyst 2960-Plus 24PC-S 35.0 34.8 35.2 34.9
Cisco Catalyst 2960-Plus 24LC-S 25.9 25.7 26.1 25.8
Cisco Catalyst 2960-Plus 48TC-S 29.9 29.7 30.2 29.8
Cisco Catalyst 2960-Plus 24TC-S 18.8 18.7 19.1 18.8
*
Using ATIS-0600015.03.2009 methodology.
Disclaimer: All power consumption numbers were measured under controlled laboratory conditions and are provided as an
estimate.
Note: The wattage rating on the power supply does not represent actual power draw. It indicates the maximum
power draw possible by the power supply. This rating can be used for facility capacity planning. For PoE switches,
cooling requirements are smaller than total power draw because a significant portion of the load is dissipated in
the endpoints.