Configuring the NAM
Configuring a WAAS Monitored Server
WAAS monitored servers specify the servers from which WAAS devices export traffic flow data to the
NAM monitors. To enable WAAS monitoring, you must list the servers to be monitored by the NAM
using the WAAS device's flow monitoring.
Note The NAM is unable to monitor WAAS traffic until you set up WAAS monitored servers. The NAM
displays the status of WAAS devices as pending until you set up WAAS monitored servers.
This section includes the following topics:
• Adding a WAAS Monitored Server, page 1-10
• Deleting a WAAS Monitored Server, page 1-10
Adding a WAAS Monitored Server
You can add a WAAS monitored server.
Step 1 Choose Configure > Network Analysis Module > Basics > Monitored Servers. The WAAS Servers
window appears.
Step 2 Choose Select All to add all the servers or select the required servers from the list.
Step 3 Click the Add button.
Deleting a WAAS Monitored Server
To delete a WAAS monitored server data source:
Step 1 Choose Configure > Network Analysis Module > Basics > Monitored Servers.
The WAAS Servers window appears.
Step 2 Choose the monitored WAAS server to delete, and click the Delete button.
A confirmation dialog box displays to ensure you want to delete the selected WAAS monitored server.
Step 3 Click the OK button to delete the WAAS monitored server.
Synchronizing Classifiers and Applications
You can synchronize the WAAS classifier and application definitions with the application and
application groups in the NAM. A classifier and an application in WAAS are equivalent to an application
and application group respectively in the NAM. WAAS applications and classifier definitions from the
device group specified during the setup configuration are matched with those in the NAM server that
WAAS is connected to. WAAS classifiers can contain source and destination IP addresses while the
NAM recognizes an application on the basis of port numbers. Hence, only the WAAS classifiers that
contain port numbers are synchronized.
You can view the results of the synchronization by following these steps: