System.monitoring.maxReports Maximum number of completed or failed report instances to store
for each custom report. The default is 10 report instances.
System.monitoring.monthlyCons
olidationFrequency
How often (in days) the WAAS Central Manager consolidates
daily monitoring records into monthly records. If this setting is set
to 1, the WAAS Central Manager checks if consolidation needs to
occur every day, but only performs consolidation if there is enough
data for consolidation to occur. The default is 14 days.
When a monthly data record is created, the corresponding daily
records are removed from the database. Consolidation occurs only
if there is at least two calendar months of data plus the
consolidation frequency days of data. This ensures that the WAAS
Central Manager always maintains daily data records for the past
month and can display data on a day level granularity for the last
week.
For example, if data collection starts on February 2nd, 2006 and
System.monitoring.monthlyConsolidationFrequencyis set to 14,
then the WAAS Central Manager checks if there is data for the past
two calendar months on the following days: Feb 16th, March 2nd,
March 16th, and March 30th. No consolidation will occur because
there is not enough data on these days.
On April 13th, however, two calendar months of data exists. The
WAAS Central Manager then consolidates data for the month of
February and deletes the daily data records for that month.
System.monitoring.recordLimitD
ays
Maximum number of days of monitoring data to maintain in the
system. The default is 1825 days.
System.monitoring.timeFrameSet
tings
Default time frame to be used for plotting all the charts. Settings
saved by the user will not be changed. The default is Last Hour.
System.registration.autoActivatio
n
Status of the automatic activation feature, which automatically
activates WAAS and WAAS Express devices that are registered to
the Central Manager. The default is true (devices are automatically
registered).
System.rpc.timeout.syncGuiOper
ation
Timeout in seconds for the GUI synchronization operations for the
Central Manager to WAE connection. The default is 50 seconds.
System.security.maxSimultaneou
sLogins
Maximum number of concurrent WAAS Central Manager sessions
permitted for a user. Specify 0 (zero, the default) for unlimited
concurrent sessions. A user must log off the Central Manager to
end a session. If a user closes the browser without logging off, the
session is not closed until after it times out after 120 minutes (the
timeout is not configurable). If the number of concurrent sessions
permitted also is exceeded for that user, there is no way for that
user to regain access to the Central Manager GUI until after the
timeout expires. This setting does not affect CLI access to the
Central Manager device.
System.security.webApplicationF
ilter
Status of the web application filter, which rejects any javascript,
SQL, or restricted special characters in input. The default is false.
Table 1-4 Descriptions for System Configuration Properties (continued)
System Property Description