Datasheet

© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 6 of 9
Category Cisco VG350 Cisco VG224 Cisco VG204XM and VG202XM
Power
AC input voltage 100- to 240-VAC autoranging 100 to 240 VAC 100 to 240 VAC
AC input current (maximum) 7.1 to 3.0 amps 1 amp 0.5 amp
DC input voltage - 12V 12V
Frequency 47 to 63 Hz 50 to 60 Hz 50 to 60 Hz
Power dissipation 230 watts (maximum consumption)
(power supply rated for 540W
capacity)
60W 30W
Redundant power supply Optional integrated RPS External 12-VDC UPS -
Physical
Width 17.25 in. (438.15 mm) 17.5 in. (444.5 mm) 8.81 in. (223.8 mm)
Height 5.25 in. (133.35 mm) 1.75 in. (44.4 mm) (add 0.17 in. for
optional rubber feet)
1.78 in. (45.2 mm) with rubber feet
Depth 18.75 in. (476.25 mm) 13.5 in. (342.9 mm) 8.13 in. (206.5 mm)
Weight (maximum) 48.08 lb 11 lb (4.106 kg) 2.98 lb (1.351 kg)
Mounting 3 rack units (3RU), 19 in.; EIA 23 in. Rack- and wall-mountable Desktop- and wall-mountable
Environment
Operating temperature 32 to 104ºF (0 to 40ºC) 32 to 122ºF (0 to 50ºC) 32 to 104°F (0 to 40°C)
Nonoperating temperature -40 to 158ºF (-40 to 70ºC) -40 to 185ºF (-40 to 85ºC) -22 to 149°F (-30 to 65°C)
Operating humidity 5 to 95% 5 to 95% noncondensing 10 to 85% noncondensing
Noise level (maximum) Sound pressure: 57.6 dB typical,
77.6 dB maximum
Sound power: 67.8 dB typical, 84.7
dB maximum
38-dbA @ 3 ft (0.914m) No fan, 0 db
On- or off-premises On-premises only, restricted access
area, permanent ground required, to
be installed and serviced only by
trained professionals
On-premises only, restricted access
area, permanent ground required, to
be installed and serviced only by
trained professionals
On-premises only, permanent
ground required, to be installed
and serviced only by trained
professionals
Compatibility
Cisco IOS Software Release 15.2(4)M or later 12.3(4)T or later 15.3(2)T or later
Cisco Unified
Communications Manager
version
8.6.2(SU2), 9.0.1, or later 3.3.3 SR2 or later 6.1.3, 7.0.1 or later
Cisco Unified
Communications Manager
Express version
7.1, 8.0, or later 4.3.2 or later 7.0.1 or later
Tip and Ring Interfaces for Each FXS Port (SLIC)
Interface type FXS (on-premises connection only)
(RJ-21)
(Optional high-speed WAN interface
card [HWIC] FXS modules on
motherboard have RJ-11
connectors.)
FXS (on-premises connection only) FXS (on-premises connection
only)
Address signaling formats In-band dual tone multifrequency
(DTMF)
Out-of-band pulse (8-12 pulses per
second [pps])
In-band DTMF
Out-of-band pulse (8-12 pps)
In-band DTMF
Out-of-band pulse (8-12 pps)
FXS signaling formats Part numbers SM-D-72FXS and
SM-D-48FXS-E support loop-start
and ground-start signaling.
HWIC slots on motherboard support
FXS loop-start, ground-start, and
DID signaling.
Loop-start and ground-start signaling Loop-start and ground-start
signaling