Installation guide
Table Of Contents
- CiscouBR7200 Series Universal Broadband Router Wireless Modem Card and Subsystem Installation an...
- If You Need More Information
- Wireless Modem Card and Subsystem Overview
- Field-Replaceable Units
- Installation Prerequisites
- Removing and Installing the Wireless Modem Card
- Installing the Power Feed Panel
- Configuring a Wireless Modem Card
- Command Reference
- Syntax Conventions
- Startup Commands
- Installation and Configuration Commands
- Operating Commands
- Monitoring the System
- Troubleshooting
- show controllers radio
- radio histogram
- radio byteErrorHist
- show interfaces radio (histspec)
- show interfaces radio (histdata)
- debug radio
- Images and Image Repositories
- radio image-add
- radio image-move
- show interfaces radio (imagehdr)
- show radio repository
- radio snapshot
- radio scope-output
- radio timeline
- show interfaces radio (tlspec)
- show interfaces radio (tldata)
- Regulatory Compliance and Safety Information
- FCC Registration and Requirements
- Translated Safety Warnings
- Short-Circuit Protection Warning
- Disconnect Device Warning
- Lightning Activity Warning
- Installation Warning
- Jewelry Removal Warning
- Supply Circuit Warning
- Service Personnel Warning
- Product Disposal Warning
- Faceplates and Cover Panel Requirement
- Chassis—Rack-Mounting and Servicing Warning
- Restricted Area Warning
- Earthed Conductor Warning
- Power Cabling Warning
- Ground Connection Warning
- Power Supply Wiring Warning
- Copper Conductors Warning
- Exposed DC Power Wire Warning
- 48 VDC Power System Warning
- SELV-IEC 60950 DC Power Supply Warning
- DC Power Disconnection Warning
- DC Input Wiring Warning
- Ground Wire Connection Warning
- Ground Conductor Warning
- No. 26 AWG Wire Warning
- Coaxial Cable Specification Warning
- Transverter Location Warning
- Obtaining Documentation
- Obtaining Technical Assistance

22
Cisco uBR7200 Series Universal Broadband Router Wireless Modem Card and Subsystem Installation and Configuration
78-6030-03
Installing the Power Feed Panel
Wall-Mounting the Power Feed Panel
To wall-mount the unit, use the same brackets as those used to install the power feed panel in an
equipment rack.
Use the following steps to wall-mount the power feed panel:
Step 1 Attach the brackets to both sides of the power feed panel. (See Figure 17.)
Figure 17 Attaching the Wall Mount Brackets
Step 2 Attach the power feed panel to the wall (see Figure 18), using screws and anchors you provide. To best
support the power feed panel and cables, make sure the power feed panel is attached securely to a
vertical wall stud or to a firmly attached plywood mounting backboard. This position will prevent the
unit from pulling away from the wall when the cables are attached.
Note To meet safety requirements, the power feed panel must be installed with the rear panel
connectors facing up.
Figure 18 Wall-Mounting the Power Feed Panel
24269
IN
DIVERSITY
CONTROL
ODU
MC
MC
27296
OFF
OFF
ON
ON
CAUTION: This equipment has a connection between the
earthed conductor of the d.c. supply circuit and the earthing
conductor. See installation instructions.
PWR
ON
PWR
ON
DIVERSITY
MC
MC
MAIN
MAIN
DIVERSITY
CONTROL
ODU
ODU
MC
MC
INPUT
CAUTION
USE COPPER
CONDUCTORS ONLY
OUTPUT
-48 ,7A
ODU
-48v 15a, 720VA
OUTPUT
-48 ,7A
ODU