Installation guide

Table Of Contents
10
Cisco uBR7200 Series Universal Broadband Router Wireless Modem Card and Subsystem Installation and Configuration
78-6030-03
Installation Prerequisites
Wireless Modem Card
You need the following tools and parts to remove and replace a wireless modem card. If you need
additional equipment, contact a service representative for ordering information.
New wireless modem card
Number 2 Phillips screwdriver
SMA production torque wrench
Your own electrostatic discharge (ESD)-prevention equipment or the disposable grounding wrist
strap included with all upgrade kits, FRUs, and spares
Antistatic mat or surface
Static shielding bag
Shielded CAT-5 cable with RJ-45 connectors and plenum-rated coaxial cable with SMA connectors
for connections between the modem card and the power feed panel. (Standard sets of these cables
can be purchased from Cisco.)
Note If you are replacing a wireless modem card, these cables are already installed.
Power Feed Panel
You need the following tools and parts to install the power feed panel in an equipment rack or on a wall.
If you need additional equipment, contact a service representative for ordering information.
Power feed panel
Number 2 Phillips screwdriver
Bracket kit (provided)
Rack- or wall-mount screws
1/8-inch flat-blade screwdriver
5/16-inch open-end wrench
SMA production torque wrench
50-ohm coaxial cables with N-type (male) connectors for IF control
Shielded CAT-5 outdoor-rated control cables with DB-9 (male) and LEMO-type (8 pin, P, 1K series)
connectors
Note If a lightning protection device is installed between the DB-9 and LEMO-type
connectors, there may be one logical cable, but two physical cables. The portion of the
cable that is located indoors does not need to be outdoor rated.
–48 VDC power supply
Ground lug (in grounding kit provided)