Datasheet

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
19
Select RAID Options
Select as follows (these choices are dependent on the number of CPUs installed):
One embedded RAID upgrade option, or
One mezzanine RAID controller, or
One mezzanine RAID controller and one external RAID controller, or
One internal RAID controller, or
One internal RAID controller and one external RAID controller
NOTE: For all valid combinations of embedded RAID, mezzanine RAID, and
internal/external RAID controller combinations, see
RAID Summary, page 56.
Table 5 Available Embedded RAID Options
Product ID (PID) PID Description
RAID Controllers
UCSC-RAID-ROM5 Onboard RAID, supporting up to 8 SAS+SATA drives. This option supports RAID 0,
1, and 10, and operates at 3 Gb/s. Operating systems supported are Windows
and Linux only (no VMware support).
UCSC-RAID-ROM55 Onboard RAID, supporting up to 8 SAS+SATA drives. This option supports RAID 0,
1, 5, and 10, and operates at 3 Gb/s. Operating systems supported are
Windows and Linux only (no VMware support).
Table 6 Available Mezzanine Card RAID Options
Product ID (PID) PID Description
Mezzanine RAID Controllers (not supported in 1-CPU systems)
UCSC-RAID-11-C220 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 5, 10, and 50
supported), operating at 6 Gbs.
Supports up to eight internal SAS+SATA drives. SAS and SATA drives can be
mixed.
Factory-configured RAID options available: RAID 0, 1, 5, and 10 (see the
RAID PIDs section in this table)
UCSC-RAID-MZ-220 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10 supported),
operating at 6 Gbs.
Supports up to eight internal SAS+SATA drives. SAS and SATA drives can be
mixed.
Factory-configured RAID options available: RAID 0, 1, and 10 (see the RAID
PIDs section in this table)
No data cache backup