Approved Configurations
The C220 M3 SFF server has an 8-drive backplane.
■ ROM5 and ROM55 embedded RAID upgrade options support up to 8 drives.
■ Mezzanine card (UCSC-RAID-11-C220) supports up to 8 drives.
■ Mezzanine card (UCSC-RAID-MZ-220) supports up to 8 drives.
■ SAS 9266CV-8i PCIe card supports up to 8 drives.
■ LSI MegaRAID SAS 9285CV-8e supports up to 8 external SAS ports (240 external drives)
Super Capacitor Option
UCS-RAID-CV-SC= LSI CacheVault Power Module for SAS 9266CV-8i. This is a spare supercapacitor.
It is the exact same supercapacitor that ships with the 9266CV-8i and
9285CV-8e cards listed earlier in this table and can be used as a replacement
or upgrade part.
RAID Configuration Options (not available for embedded RAID)
R2XX-SRAID0 Enable Single Disk Raid 0 Setting (for the following PIDs only):
■ UCS-RAID-9266CV
■ UCSC-RAID-11-C220
■ UCSC-RAID-MZ-220
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.
R2XX-RAID10 Factory preconfigured RAID option
Enable RAID 10 Setting. Requires a even number of drives (minimum of four
drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in
Table 5
Table 7 Available Plug-In PCIe Card RAID Options (continued)