Datasheet
Table Of Contents

Cisco UCS B420 M4 Blade Server
SUPPLEMENTAL MATERIAL
51
In Figure 18 (supported on 4-CPU configurations), the Storage Accelerator installed in adapter slot 2 acts as
a pass-through device, channeling two ports to each of the Fabric Extenders. In addition, two ports from
the VIC 1340 adapter are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric
Extender B. The result is 40 Gb of bandwidth to each Fabric Extender. This configuration requires 4 CPUs.
Figure 18 VIC 1340 (Cisco UCS Storage Accelerator in slot 2 and adapter slot 3 empty)
In Figure 19 (supported on 2-CPU configurations), two ports from the VIC 1340 adapter are channeled to
2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B. The result is 20 Gb of
bandwidth to each Fabric Extender. The storage accelerator in slot 3 provides no network connectivity.
Figure 19 VIC 1340 (Cisco UCS Storage Accelerator in slot 3 and adapter slot 2 empty)
VIC 1340 Adapter
adapter slot #1 for VIC 1340
Port Group A Port Group B
CPU1
PCIe x16
CPU 2
No Adapter
Installed
adapter slot #3
CPU 3
2208XP Fabric
Extender B
2208XP Fabric
Extender A
EMPTY
10G KR
10G KR
10G KR
10G KR
10G KR
10G KR
10G KR
10G KR
Cisco UCS Storage Accelerator
10G KR
10G KR
10G KR
10G KR
adapter slot #2
VIC 1340 Adapter
adapter slot #1 for VIC 1340
Port Group A Port Group B
CPU1
PCIe x16
CPU 2 CPU 3
2208XP Fabric
Extender B
2208XP Fabric
Extender A
10G KR
10G KR
10G KR
10G KR
Cisco UCS Storage Accelerator
adapter slot #3
EMPTY
No Adapter
Installed
adapter slot #2