Cisco UCS B420 M4 Blade Server
CONFIGURING the SERVER
17
Supported Configurations
1
(1) Four Drive Bays with RAID 0, 1, 10
■ Choose the following:
— One UCSB-MRAID12G. This provides two drive bays installed on the left side of the
blade server (viewed from the front). The RAID controller is integrated in the drive
bays and provides RAID 0,1,10.
— One UCSB-LSTOR-PT. This provides two drive bays installed on the right side of the
blade server (viewed from the front) and includes a passthrough connector that
allows the drives to be managed from the RAID controller in UCSB-MRAID12G (RAID
0,1,10).
(2) Two Drive Bays with RAID 0, 1, 10
■ Choose the following:
— One UCSB-MRAID12G. This provides two drive bays installed on the left side of the
blade server (viewed from the front). The RAID controller is integrated in the drive
bays and provides RAID 0,1,10. The two right-hand bays are fitted with blanking
panels to maintain proper cooling airflow.
(3) No Drive Bays
■ System is installed with blanking panels.
Notes
1. Any empty drive bays must be fitted with blanking panels to maintain proper cooling airflow.