Datasheet

Cisco UCS C460 M4 High-Performance Rack-Mount Server
28
CONFIGURING the SERVER
Table 15 PCIe Expansion Slot Priorities
PCIe Card Type
Primary Slot
(install here first, top to
bottom order)
Secondary Slot
(install here second,
top to bottom order)
Alternate Slots
(install top to bottom
order; may have
reduced functionality)
LSI MegaRAID Card Internal RAID slot
(see Figure 7 on page 56)
Low-profile x8
Network Card or
RAID card for
external drives
Slot 5 (riser 1)
Slot 10 (riser 2)
Slot 8 (riser 2)
Slot 9 (riser 2)
Slot 2 (riser 1)
Slot 7 (riser 2)
Slot 1 (riser 1)
Slot 6 (riser 2)
Slot 3 (Riser 1)
Slot 4 (riser 1)
VIC cards Slot 4 (Riser 1) Slot 5 (riser 1)
Slot 9 (riser 2)
Slot 10 (riser 2)
Slot 3 (riser 1)
Slot 8 (riser 2)
Slot 2 (riser 1)
Slot 7 (riser 2)
GPU
1
Notes . . .
1. You cannot have a GPU installed in slot 7 and at the same time have a QLE2562 HBA (N2XX-AQPCI05) installed in
slot 9.
Slots 7 and 6 (riser 2)
Slots 2 and 1 (riser 1)
UCS Storage
Accelerators
2
Fusion ioDrive2
Fusion ioMemory3
2. Fusion ioDrive2 and Fusion ioMemory3 storage accelerators cannot be mixed.
Slot 8 (riser 2)
Slot 2 (riser 1)
Slot 8 (riser 2)
Slot 2 (riser 1)
Slot 7 (riser 2)
Slot 6 (riser 2)
Slot 1 (riser 1)
Slot 9 and 10 (riser 2)
Slot 5 (riser 1)
Slot 7 (riser 2)
Slot 6 (riser 2)
Slot 1 (riser 1)
Slot 9 and 10 (riser 2)
Slot 5 (riser 1)
Slot 3 (riser 1)
3
Slot 4 (riser 1)
Slot 3 (riser 1)
1
Slot 4 (riser 1)
3. This slot is a x4 slot, so there is some performance degradation when installing a storage accelerator in this
slot.